Shangziyi Fifth FactoryUQK-01The floating ball liquid level controller is suitable for controlling the liquid level of various containers. When the liquid level reaches the upper and lower switching values, the controller contact sends an on-off switch signal.The controller is not suitable for media that have strong corrosive effects on materials such as brass and stainless steel, as well as media containing magnetic impurities. structural principleUQKThe series floating ball liquid level controller consists of two parts: a floating ball group and a contact group that are isolated from each other. When the measured liquid level rises to the upper switching point,float ball1Rising accordingly,Make the magnetic steel at its end2Swing downwards,Through magnetic force,Deny installation on the casing3Same magnetic pole inside4Swing up and down, with the moving contact at the other end5Right at the static contact point2-2Interconnectivity. When the liquid level drops to the cut-off point, the situation is exactly the opposite, the static contact point1-1Connected. The area between the upper and lower tangent points is called the displacement area.

Shangziyi Fifth FactoryUQK-01The floating ball liquid level controller is suitable for controlling the liquid level of various containers. When the liquid level reaches the upper and lower switching values, the controller contact sends an on-off switch signal.
The controller is not suitable for media that have strong corrosive effects on materials such as brass and stainless steel, as well as media containing magnetic impurities.
structural principle
Shangziyi Fifth FactoryUQK-01The float level controller consists of two separate parts: a float group and a contact group that are isolated from each other.
When the measured liquid level rises to the upper switching point,float ball1Rising accordingly,Make the magnetic steel at its end2Swing downwards,Through magnetic force,Deny installation on the casing3Same magnetic pole inside4Swing up and down, with the moving contact at the other end5Right at the static contact point2-2Interconnectivity. When the liquid level drops to the cut-off point, the situation is exactly the opposite, the static contact point1-1Connected. The area between the upper and lower tangent points is called the displacement area.

| power supplyAnd contact capacity | |||||||
| UQK- 01/01GFloating ball liquid level controller |
| 1 | 150 | ≤14 | non-adjustable | level | 220VAC 200W 100VDC 150W |
| UQK-02/02GFloating ball liquid level controller |
| 1 | 150 | 25~550 | Adjustable levels | level | |
| UQK-03/03GFloating ball liquid level controller |
| 1 | 150 | 8~1000 | Stepless adjustment | vertical |