Overview
The 80G high-frequency radar level gauge from Shanghai Instrument Factory 5 has the advantages of low maintenance, high performance, high accuracy, high reliability, and long service life. Compared with contact instruments such as capacitors and heavy hammers, it has superior performance. The transmission of microwave signals is not affected by the atmosphere, so it can meet the requirements of harsh environments such as volatile gases, high temperature, high pressure, steam, vacuum, and high dust during the process. This product is suitable for harsh environments such as high temperature, high pressure, vacuum, steam, high dust, and volatile gases. Continuous measurements can be taken for different material levels. The main technical indicators of the 80G high-frequency radar level gauge are comparable to or better than similar products at home and abroad, and it is easy to install and debug. It can be used as a single unit or in a network, and can be widely used in industries such as metallurgy, building materials, energy, petrochemicals, water conservancy, and grain.
Product Details
The 80G high-frequency radar level gauge from Shanghai Instrument Factory 5 has the advantages of low maintenance, high performance, high accuracy, high reliability, and long service life. Compared with contact instruments such as capacitors and heavy hammers, it has*Sex. The transmission of microwave signals is not affected by the atmosphere, so it can meet the requirements of harsh environments such as volatile gases, high temperature, high pressure, steam, vacuum, and high dust during the process. This product is suitable for harsh environments such as high temperature, high pressure, vacuum, steam, high dust, and volatile gases. Continuous measurements can be taken for different material levels. The main technical indicators of the 80G high-frequency radar level gauge are comparable to or better than similar products at home and abroad, and it is easy to install and debug. It can be used as a single unit or in a network, and can be widely used in industries such as metallurgy, building materials, energy, petrochemicals, water conservancy, and grain.

上海仪表五厂

Three detection methods for normal installation of FM radar level gauge
On site inspection should observe whether the actual working conditions on site are suitable for the application of radar level gauge products, and confirm whether the installation position is correct and whether the installation environment has an impact on the use of the instrument, in order to avoid malfunctions that may occur after * * * and affect its use. In addition to on-site inspection of radar level gauges, other instruments also need to perform this task, which is relatively basic.
Next, conduct a power on inspection. Because after power on, it can be observed whether the radar level gauge gradually enters and displays normally according to the normal startup procedure. And many unexpected incidents occur due to power on reasons, or simply not being powered on, causing the instrument to malfunction. If allowed on site, it is also possible to observe whether the level gauge changes linearly and other parameters through feeding and discharging.
Next, perform a connection check. This overlaps with on-site inspection, where the linearity of the level gauge can be observed by connecting the corresponding software. Generally speaking, instruments with buttons can also achieve this function. Users can also use professional instruments to check its connection and determine whether the radar level gauge is operating normally.
In addition to the above methods, there are many other ways to detect the installation of the radar level gauge, so that the instrument can be used normally without affecting the work progress.

上海仪表五厂

Instructions for Using 80G High Frequency Radar Level Gauge
1. This instrument is used outdoors, so it is recommended to install a sunshade or protective box to prevent the LCD screen from aging due to exposure to sunlight over time. If used in an environment with corrosive gases, it is necessary to install an anti-corrosion jacket and tighten the outer shell and inlet and outlet terminals of the instrument. Radar level gauges should be selected for use in environments with corrosive gases or liquids, or in coastal or offshore environments, and should be of anti-corrosion type.
2. Wire and cable protection pipes should be sealed with radar level gauges to prevent water accumulation and to prevent being bitten by rodents such as mice.
3. Although the instrument itself has lightning protection devices, it is recommended to install dedicated lightning protection devices at the inlet and outlet of the instrument when using the radar level gauge in areas with frequent lightning strikes.
4. When the instrument is used in extremely hot and cold places, where the ambient temperature may exceed the working requirements of the instrument, it is recommended to install high and low temperature devices around the level gauge.
5. The radar should be perpendicular to the liquid level being measured, and there should be no other obstacles within the conical range of the radar's electromagnetic wave emission.
6. If the FM radar level meter is used in the environment of dust, steam, fog, foam, floating objects on the liquid surface, stirring and waves on the liquid, please contact the technical service department of the company in advance to treat it differently.