Second class standard platinum rhodium 30 platinum rhodium 6 thermocouple

NegotiableUpdate on 04/27
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The second-class standard platinum rhodium 30 platinum rhodium 6 thermocouple is mainly used as a standard for temperature value transmission in the temperature range of 1100-1500 ℃. The second-class standard platinum rhodium 30 platinum rhodium 6 thermocouple is also used for precision temperature measurement in this temperature range. The second-class standard platinum rhodium 30 platinum rhodium 6 thermocouple (hereinafter referred to as the standard double platinum rhodium thermocouple) has a positive electrode (BP) of a platinum rhodium alloy containing 30% rhodium and a negative electrode (BN) of a platinum rhodium alloy containing 6% rhodium.

Product Details

Second class standard platinum rhodium30Platinum rhodium6thermocouple
Second class standard platinum rhodium30-Platinum and rhodium6Thermocouples are mainly used as standard devices1100-1500The ℃ temperature range is used for temperature value transmission,Second class standard platinum rhodium30-Platinum and rhodium6ThermocoupleIt is also used for precise temperature measurement in this temperature range.
Second class standard platinum rhodium30-Platinum and rhodium6thermocouple(Hereinafter referred to as standard double platinum rhodium thermocouple)Its positive pole(BP)Containing rhodium30%Platinum rhodium alloy, negative electrode(BN)Containing rhodium6%Platinum rhodium alloy.
Second class standard platinum rhodium30-Platinum and rhodium6ThermocoupleMain technical parameters:
modelname
Accuracy level
Main technical parameters
WRRB-2
Second class standard platinum rhodium30-Pt-Rh6Thermocouple
second
E1100℃)=5.780soil0.025mV
E
1500℃)=10.099scholar0.040mV
Second class standard platinum rhodium30-Platinum and rhodium6The stability of thermocouples depends on their1500The change in thermoelectric potential at ℃ determines that the annual variation does not exceed18μV.
national standard:JJG167-1995Standard Platinum Rhodium30Platinum rhodium6Thermocouple Verification Regulations
Note: Waste platinum resistance thermometers, standard thermocouple wires, and industrial waste platinum rhodium wires can be exchanged for new or recycled at a fixed price.