Welcome Customer !

Membership

Help

Huai'an Hengrun Automation Instrument Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Huai'an Hengrun Automation Instrument Co., Ltd

  • E-mail

    hryb88@126.com

  • Phone

    17766446509

  • Address

    No. 8-8 Kejian Road, Jinhu Industrial Concentration Zone, Jiangsu Province

Contact Now

Safety barrier isolator

NegotiableUpdate on 05/08
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Safety Barrier Isolator Intelligent Vacuum Pressure Calibration Instrument Product Model: HR-NPEX Series Product Quotation: Obtained clicks: 316 times Product Features: HR-NPEX Series Isolation Safety Barrier will output single or independent dual current/voltage signals from hazardous areas through isolation transmission to the safety area. It can also be connected to the safety area through a configured communication interface for serial communication networking.

Product Details

Safety barrier isolator

安全栅
Product model:
HR-NPEX series
Product quotation:
Clicked:
316 times
Product features:
The HR-NPEX series isolated safety barrier outputs single or independent dual current/voltage signals from hazardous areas through isolated transmission to the safety area. It can also be connected to the safety area through a configured communication interface for serial communication networking. It is an intelligent safety barrier product, and users can set the input signal type and output range of this product through a dedicated programmer or computer.
Intelligent vacuum pressure calibratorDetailed information:

1、 Product Overview:

The HR-NPEX series safety barrier isolates and transmits single and dual channel thermal resistance signals from hazardous areas, and then outputs single and dual current or voltage signals to the safe area.
The HR-NPEX series safety barriers are connected to various domestic and imported two - and three wire transmitters, current sensors, temperature measuring elements, and other instruments, and are used as associated equipment for safety and explosion-proof systems. Widely used in safety and explosion-proof systems for intrinsically safe instrument products in chemical, oilfield, metallurgical, natural gas, power and other industries.The intelligent safety barrier has an online fault self diagnosis function. Users can set the input signal type and output range of this product through a dedicated handheld Chinese programmer, and perform serial communication networking in the safety zone through the configured communication interface.


2、 Characteristics of safety barriers:


1. Low power consumption and low cost.
2. Can isolate primary instruments such as transmitters with 4-20mA

3. Support Hart communication
4. No external power supply is required, it can be directly used in 4-20mA circuits.
5. Adopting a three party isolation method, there is no need for a system grounding line.
6. Isolated safety barriers have stronger input signal processing capabilities and can accept and process signals from thermocouples, thermistors, frequencies, and other sources.
7. The isolated safety barrier can output two signals that are mutually isolated, providing them to two devices using the same signal source, ensuring that the signals of the two devices do not interfere with each other, and improving the electrical safety insulation performance between the connected devices.
8. The requirements for instruments in hazardous areas have been significantly reduced, and there is no need to use isolated instruments on site.


3、 Safety barrier parameters:


Input signal: 4-20mADC, distribution voltage 18.5V-28.5VDC
Output signal: 4-20mADC (load resistance ≤ 500 Ω) or 1-5VDC (load resistance ≥ 250K Ω)
Basic error: ± 0.2% FS
Explosion proof mark: [Exib] Ⅱ CT6
Explosion proof rating: 220V (AC/DC)
Rated value of intrinsic safety circuit: maximum open circuit voltage ≤ 30V, maximum short-circuit current ≤ 30mA
Power consumption: ≤ 2W
Power supply voltage: 24VDC ± 5%
Temperature drift: ≤ 0.01% FS/℃
Environmental temperature: 0-50 ℃
Relative humidity: ≤ 85% RH
Working environment: frequency ≤ 25Hz, vibration amplitude (double) ≤ ± 0.1mm, external magnetic field ≤ 400A/M, no corrosive gases or impurities around
Installation method: Rear mounted card (DIN35 track) or rack mounted


4、 Selection of safety barriers:

Model

Remarks

NPEX

LCD detection end safety barrier

Thermal resistance input

Channel

Default is single channel

D

Dual input channel

First output

1

4-20mA

2

1-5V

3

0-10mA

4

0-5V

5

0-10V

6

0-20mA

7

1: 1 Resistance signal output

second output

Default no second output

1

4-20mA

2

1-5V

3

0-10mA

4

0-5V

5

0-10V

6

0-20mA

Communication and alarm functions (if this option is selected, there will be no second output function)

Default is no communication function

T1

485 communication (single output only)

T2

232 communication (single output only)

A1

Alarm relay output (single output only)

A2

Alarm relay output (dual output)

The following figure shows the safety barrier at the single in and single out inspection end