SX stainless steel ultraviolet disinfection vehicle

Product Details

嵌入式等离子体动态空气消毒器

Product characteristics

1Product model:SX

2Input power(VA):≤150VA

3UV lamp tube model and quantity:ZW30S19W*2

4Lamp arm length(mm):915±2

5Lamp length(mm):894

6External dimensions(mm):340*3601060

7Lamp arm adjustment angle(︒):0-180

8Universal Wheel:4*360 degreesPlastic Wheel

9. Box material: Nostainless steel

10The outer surface should be flat and smooth, without defects such as sharp edges, burrs, cracks, etc. Spray painted parts are shiny and have a bright colorUniform, without detachment, sagging, or scratchesThe word markings are clear and accurate.

11. Working conditions: Power supply 220V ± 22V 50HZ ± 1HZambient temperature5-40℃Relative humidity:≤80%

12. Ultraviolet radiation wavelength: 253.7nm

13. Applicable area: ≤20㎡

14. Disinfection timing range: 0-120 minutes, with a maximum timing error of<15 minutes

15. The ultraviolet lamp used in the disinfection vehicle complies with GB19258-Regulations of 2012

16. ★Sterilization effect testing data(Provide testing report)

term eye

index

Vertically below the lamp tube1m away, carrierThe action of Staphylococcus aureus60 minute killing logarithmic value

3.00

Vertically below the lamp tube1m away, carrierThe action of Escherichia coli60 minute killing logarithmic value

Vertically below the lamp tube1m away, carrierThe action of Pseudomonas aeruginosa60 minute killing logarithmic value

Vertically below the lamp tube1m away, carrierBacillus subtilis var. niger spore formation90 minute killing logarithmic value

Vertically below the lamp tube1m awayOn the carriernatural bacteriarole60minThe logarithmic value of killing

1.00

17UV intensity detection data(Provide testing report)

UV tube turned on20After minutes, itThe irradiation intensity is(Vertically below)1m away)139uw/c-142uw/c

UV tube turned onafterWithin 60 minutesThe irradiation intensity is(Vertically below)1m away)141uw/c-144uw/c