STAN-SSH high specular reflectance standard plate can be used to measure the reflectance of photosensitive substrates, optical coatings, machined metals, semiconductor materials, and other materials. The surface has high reflectivity ..
STAN-SSH High Mirror Reflectivity Standard Plate
STAN-SSH high specular reflectance standard plate can be used to measure the reflectance of photosensitive substrates, optical coatings, machined metals, semiconductor materials, and other materials, with a high specular surfaceReference for reflectivity values of objects. STAN-SSL provides~85-90% reflectivity in the wavelength range of 200-800 nm and 800-2500 nm
~85-98% reflectivity.
There are two styles of STAN-SSH, STAN-SSH type and NIST traceable STAN-SSH-NIST type.The NIST type STAN-SSH-NIST is calibrated according to a NIST standard (NIST number NIST38060S, s/n 99G16) with an accuracy of approximately 0.1% between 250-2500 nm. giveSTAN-SSH-NIST also delivers a calibration manual, a reflectance value data table as a function of wavelength, and a disk containing data to the userIt can be transferred to the operating software of the ocean optical spectrometer.It is recommended that users regularly calibrate STAN-SSH-NIST.The STAN-SSH photosensitive substrate has a diameter of 1.25 'and is placed in a hard 1.5' x 0.75 'blue anodized aluminum box with a cover screwed on for protection.
hints
When using ocean optical spectrometers, STAN-SSH is limited to 200-1100 nm.
When setting a high reflectivity benchmark, STAN-SSH can be usedAlthough the aluminum film of STAN-SSH is protected by an outer coating, users should still be careful when using it to ensure that the standard surface is not damaged. Do not use hands or objectsContact the surface to avoid contamination and damage. When cleaning the surface of STAN-SSH, first blow off the dirt and dust on the surface with high-pressure gas, and then use the traction cleaning method to remove the surfaceFingerprints and fixed residues on the surface. The traction cleaning method is to slowly pull the lens surface with lens paper dipped in acetone or alcohol. As long as the operation is correct and the solvent evaporates evenlyWill not leave any trailing or blemishes on the surface of the lens.The exposed metal layer is very clean and precise, and cannot be cleaned using this method. Fingerprints and dirt can cause permanent damage to it, so users must be very careful when operating STAN-SSHBe careful to extend its lifespan.STAN-HHOLDER is an accessory used to fix standards during measurement, making it easy to use.