Welcome Customer !

Membership

Help

Zhongshi Walker (Tianjin) Technology Development Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Zhongshi Walker (Tianjin) Technology Development Co., Ltd

  • E-mail

  • Phone

  • Address

    No. 2, Haitai Innovation 6th Road, Huayuan High tech Zone, Tianjin

Contact Now

SPE Vacuum Manifold

NegotiableUpdate on 02/05
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Solid phase extraction (SPE) is the process of purifying a target substance by utilizing the differential adsorption ability of the analyte in different media. It effectively separates the target substance from interfering components, greatly enhancing the detection ability of the analyte, especially trace analytes, and improving the recovery rate of the tested sample. SPE technology has developed since its emergence in the late 1970s ..
Product Details


Solid phase extraction(SPESolid Phase Extraction)It is to purify the target substance by utilizing the differential adsorption ability of the analyte in different media, effectively separating the target substance from interfering components, greatly enhancing the analysis of the analyte, especiallytrace analysisThe detection ability of the substance has improved the quality of the tested samplerate of recovery.SPETechnology since the last century70Since its emergence in the late 1960s, it has developed rapidly and is widely used in fields such as environment, pharmaceuticals, clinical medicine, and food


The basic working principle is shown in the following figure:samplePre rinsingSample aboveWashing

elutionThe World Walker launchedSPE-10AThe automatic solid-phase extraction device fully follows the working principle of solid-phase extraction and can process up to the same time each time6-12A sample. Throughout the entire sample processing process, the device uses a high-power, high-precision stepper motor to precisely control the flow rate of the small column, with an accuracy of up to

0.1ml/minThis fundamentally overcomes the traditional manual solid-phase extraction device (negative pressure or positive pressure), which is affected by the difference in resistance (pressure) between different small columns, resulting in a huge difference in flow rate between columns. The flow rate of a single small column cannot be accurately controlled, ultimately leading to the embarrassing result of wasting time, manpower, and material resources, but the experimental results cannot be guaranteed.at the same time8SPE-10A

The automatic solid-phase extraction device adoptsInch full touch screen control, can edit and save methods, up to ten extraction steps can be set, and extraction speed and volume can be independently set. During the extraction and rinsing process, each step is accompanied by a beep to remind users to proceed to the next step in a timely manner.In addition,SPE-10AThe automatic solid-phase extraction device adopts patented technology1PTE3Joint, also applicable to6

10mlExtraction columns of different volumes allow users to freely switch between different products.

SPE-10A

Characteristics of Automatic Solid Phase Extraction Device1. Adopting positive pressure stepper motor infusion technology to ensure stable flow rate, high precision, and repeatability;2. Semi automatic operation requires manual switching of solvents

SPE6Activation, loading, elution, cleaning, etc. of the column;123. HavingA(Extraction channel, capable of simultaneous extraction

6-12

A sample;

4. Support step-by-step elution function, which can achieve multi-step elution;

5. Can store ten methods, call up and use, automatically set;

6. All instrument operations are completed by the control panel, and operators only need to follow the prompts to change the liquid, greatly saving manpower;

7. Automatic cleaning function to avoid cross contamination

8. It can extract liquid samples such as groundwater, surface water, wastewater, fruit juice (even containing suspended solids);9. The performance is the same as that of fully automatic products, but the price advantage is obvious and the cost-effectiveness is higher;

SPE-10A

6Main technical indicators of automatic solid-phase extraction device

Channel

thoroughfare

flow rate range

0-10mL/min

solvent type

no limit

Sample volume

0.1mL-9999ml

Receiving volume

0-60mL

Support samples

Food, water quality, soil, body fluids, etcsealing technologyindependence

PTE

Plunger seal

Extraction Mode

Positive pressure extraction

Extraction column pressure

0-300psiExtraction column specifications

1/3/6/10/15/20/60mL

Extraction columns of other specifications

voltage

220V 50Hz

operation temperature

10-40℃Working humidity

0-90%

, without condensation

power120W

SPE-10A

Application scope of automatic solid-phase extraction device 1. Environment Insecticides and herbicides, petroleum and oils, polycyclic aromatic hydrocarbons, explosives, polychlorinated biphenyls, brominated flame retardants

Dioxins

Furan organic pollutants, phenylurea, semi volatile organic pollutants, endocrine disruptors;

2. Food

Pesticides and herbicides, pollutants in packaged beverages, pesticide residues, natural products, dietary supplements, melamine, antibiotic residues, malachite green, crystal violet, sulfonamides, quinolones, plasticizers;

3. Pharmaceutical industry

Analysis of active ingredients in liquids, analysis of extractable substances in drug packaging, vitamins and antibiotics;