Germanyecom GmbHYikang Company was established in1985In the year, the headquarters and production base are located in Iseron, Germany40Multiple countries and regions have branch offices and distributors.30For many years, Yikang Company has been dedicated to Yikang(ecom)The research and development, production, and sales of a series of portable intelligent flue gas analyzers have led Yikang Company's products to enter factories, enterprises, ships, and other places equipped with large engine devices around the world for industrial combustion analysis and measurement. As a modern industrial technology enterprise, the slogan of Yikang Company is“We create a high-quality life!”And take this slogan as the purpose of responsibility to users, employees, and the company itself.
ecom-J2KNpro TECHExpert level multifunctionalSO2 flue gas UV analyzerThe measurement methods for different gas components can be freely combined according to accuracy and measurement requirements, and five measurement methods can be integrated for simultaneous testing.
Instrument Features
●One instrument can simultaneously select sensors for electrical chemistry, infrared, ultraviolet, catalysis and other technologies
●adopt868MHzWireless remote control, convenient and fast, interference free, with a transmission distance of up to50rice
● NOTheNO2TheNOxTheSO2UV optical sensor measurement
● COCan simultaneously select electrochemical and infrared sensors for measurement
●High power sampling pump, with a maximum vacuum degree of up to-60KPaCapable of sampling high negative pressure flue gas
●Equipped with automatic pressure and temperature compensation functions to ensure the accuracy of measurement data
●Visual digital flowmeter, real-time display of intake flow rate, with the highest sample gas flow rate2.6L/min
●Measurement expert for clean combustion and ultra-low emissions
● The instrument can collect electrochemical, infrared, ultravioletCLD, PAS and other testing technologies are integrated to simultaneously test gases of various components.
● There is an editable intermittent testing function, which can achieve short-term simulated continuous measurement (maximum) through software editing48 hours).
● The device can automatically heat or cool according to the usage environment(0-40 ° C ambient temperature)
● Heavy sample gas filtration device
● Durable aluminum shell packaging box, equipped with wheels and hand levers for easy movement of the instrument.
Instrument performance and configuration
●Large screen colorTFTLCD screen display and backlit keyboard, fully Chinese operating system
●Double stage Peltier electronic condenser quickly removes condensed water from the sample gas, avoiding soluble gas loss and ensuring the authenticity and reliability of measurement data
● COOver range automatic shutdown and blowback protectionCOSimultaneously measuring other gases without interrupting the sensor
●Automatically calibrate sensor zero point when turned on, automatically blow fresh air when turned off
●Integrated thermal printer for fast printing of measurement data (optional needle printer)
●built-inppmThemg/m3Multiple units such as reference oxygen conversion are available for selection
●Electronic condensate water level monitoring with automatic condensate discharge function
●Smoke black measurement function and optional differential pressure flow rate measurement
●Equipped with one key zero calibration function during the measurement process
●Implemented human-machine separation to ensure the safety of testing personnel, adopting868MHzWireless technology, automatic connection and reconstruction, stable and reliable, with a maximum control distance of up to50Rice.
●Equipped with measurement data storage function, plug and play large capacity storage card
●Rechargeable battery operation, directly reading the ambient temperature
●Compliant with international and Chinese radio management technical standards and regulations, approval code:CMIT ID2011DJ0261&CMIT ID2011DJ0262
technical indicators
lOxygen and carbon monoxide (hydrogen compensation) long-life sensors
lCarbon monoxide automatic cut-off protection and flushing function (uninterrupted measurement)
lIt has editable intermittent testing function and can be edited through software Short term simulated continuous measurement (longest)48 hours).
lCan be equipped with a heating sampling system (attachment)
lBuilt in thermal fast printer
lAdopting an ultra lightweight and durable aluminum shell, there are different sizes of transport boxes to choose from. The outer packaging box can be equipped with wheels and pull rods, and can be freely moved and carried.
lComes with smoke black measurement function (smoke black measurement sampling equipment purchased separately)
option
lThe results can be measured by nitric oxide or nitrogen oxides (nitric oxide)+Nitrogen dioxide sensor for calculating nitrogen oxides
lAdditional sensor options (sulfur dioxide, hydrogen sulfide, hydrogen gas, percentage content of carbon monoxide)
lLow concentration range of nitric oxide(0-500 ppm) or nitrogen dioxide (0-100 ppm) sensors have higher resolution and accuracy
lInfrared method(NDIR direct measurement of carbon dioxide, high concentration carbon monoxide, and hydrocarbons (calibrated with methane or propane)
lMeasurement of hydrocarbons using catalytic measurement methods(Pellistor)0-4 vol. %
lMethane (infrared method)(NDIR sensor, 0-100%
lSulfur dioxide (UV electrochemical method)(EC) Sensor, 0-5000 ppm
lSulfur dioxide (UV)(UV sensor, 0-100ppm
Attachment
lSmoke sampler and transmission pipeline
lEquipped with multi-channel trachea of different lengths and nitrogen oxides/Sulfur oxide dedicated trachea, available in specifications of 3.5m, 5m, and 10m
lSampling tubes of various lengths with non heating or heating functions, as well as sampling handles (of different lengths and temperature resistance levels), are availableSpecifications such as 300mm, 500mm, 750mm, 1000mm, 1500mm, etc
lMultiple additional filter options - Includes options for measuring dense solid fuels
lMultiple temperature probes (contact sensors, surface sensors, etc.) used for temperature difference measurement (such as outflow temperature and reflux temperature) with insulation protective covers
lHeating sampling tube, includingPTFE filter and thermistor for measuring gas temperature
lHeating trachea for non-destructive gas transmission, with a maximum adjustable temperature to140℃
lHeating sampling system
UV sensor description
The measurement principle of SO2 flue gas ultraviolet analyzer is based on specific gas pairs200nmto450nmUltraviolet radiation has selective absorption. For example, sulfur dioxide(SO2)Nitrogen dioxide(NO2)Nitric oxide(NO)Aromatic hydrocarbons(benzene)And ozone(O3)All can be measured within this spectral range. This analytical principle is not affected by the interference of water vapor concentration. The ultraviolet light source adopts aluminum gallium nitride luminescence technology, which can cover a spectral range from450nmto200nmThe ultraviolet light. The absorption of ultraviolet energy by the sample gas conforms to Lambert's law-Bill's Law.
The physical structure of the ultraviolet gas sensor consists of a narrow linewidth ultraviolet light source and two receiving detectors. Among them, the reference detector continuously receivesUVThe radiation intensity is used to counteract aging effects and temperature effects. In the photometer, ultraviolet light is processed through a lens to generate parallel beams. The parallel beam is further divided into a measurement beam and a reference beam. At the end of the measuring cell, the light beam will be focused by another lens onto a high-sensitivity ultraviolet optical detector, which converts the received light energy into measurable voltage. In this way, the concentration of the measured gas can be calculated based on the absorbed ultraviolet energy in the measuring cell.
Meet the current national UV standards
● GBT 37186-2018gas analysis Determination of sulfur dioxide and nitrogen oxides---UV Differential Absorption Spectroscopy Analysis Method
● HJ 1045-2019Technical requirements and detection methods for portable ultraviolet absorption measuring instruments for fixed pollution source flue gas (sulfur dioxide and nitrogen oxides)
● HJ 1131-2020Fixed pollution source exhaust gas Determination of sulfur dioxide---Portable UV absorption method