Product Features
1. By utilizing the principle of countercurrent cooling to cool high-temperature and high humidity particles, the phenomenon of sudden cooling caused by direct contact between cold air and hot material is avoided, thus preventing surface cracking of particles. At the same time, due to the use of a closed air feeder and a large air inlet area, the cooling effect is significant;
2. Adopting a slide valve reciprocating discharge mechanism, the movement is smooth, reliable, and the residue is small;
3. Low energy consumption and easy operation;
4. After cooling, the temperature of the finished product should not exceed room temperature by+3 ℃ to 5 ℃;
5. Suitable for cooling granular materials.
Main technical and performance parameters
|
Model Parameters |
SKLN1.5 |
SKLN2.5 |
SKLN4 |
SKLN6 |
SKLN8 |
Cooling capacity (m ³) |
1.5 |
2.5 |
4.0 |
6.0 |
8.0 |
Production capacity (t/h) |
3 |
5 |
10 |
15 |
20 |
Cooling time (min) |
Not less than 10-15 |
||||
Material temperature after cooling (℃) |
Not higher than room temperature+3~5 |
||||
Air suction volume (m ³/min. t) |
34 |
||||
Equipped with power (kw) |
0.75 |
1.10 |
1.50 |
1.50 |
1.50 |
Wind turbine power (kw) |
0.55 |
0.55 |
0.55 |
0.75 |
0.75 |
SKLN Series Counterflow Cooler
SKLN series counter current cooler
Features
1. The counterflow cooling principle is adopted to cool the pellets with high temperature and moisture. Hot air touches hot pellets and cool air touches cool pellets so as to avoid the pellet surface crack caused by sudden cooling produced by direct touching between cool air and hot pellets. At the same time, the airlock is used for feeding and space of air inlet bigger, therefore it can get better cooling effects;
2.Slide reciprocating discharger has smooth and reliable discharging, low residue;
3.Low power consumption, ease of operation;
4.Pellet temperature after cooling is less than +3°C~5°C ambient temperature;
5. Capable of cooling pellets.
Main Technical Parameters
|
Model Parameters |
SKLN1.5 |
SKLN2.5 |
SKLN4 |
SKLN6 |
SKLN8 |
Volume(m³) |
1.5 |
2.5 |
4.0 |
6.0 |
8.0 |
Capacity(t/h) |
3 |
5 |
10 |
15 |
20 |
Cooling time(min) |
Less than 10-15Mins |
||||
Temperature after Cooling(°C) |
Not higher than ambient temperature +3~5 |
||||
Aspiration(m³/min.t) |
34 |
||||
Power(kw) |
0.75 |
1.10 |
1.50 |
1.50 |
1.50 |
Power of Airlock (kw) |
0.55 |
0.55 |
0.55 |
0.75 |