1: YCF-30BSKC Collection EfficiencyUsage characteristics:
SKC Collection EfficiencyETF-30B type, developed by our companyThe particle size distribution of the dust collected by the respiratory dust sampling head conforms to the BMRC curve Meet the requirements of GB16225-1996, GB16248-1996, GB16238-1996, and three national respiratory dust hygiene standards The aerodynamic diameter of the collected dust is below 7.07, and the collection rate of dust with an aerodynamic diameter of 5 is 50% Due to the special design of the scraper pump, its flow rate is stable, there is no pulse, and the measurement is accurate.
It is widely applicable to labor health supervision and testing institutions at all levels, as well as factories, mines, and metallurgy The chemical industry is used to detect the total dust concentration and respiratory dust concentration in the air of workplaces This instrument has the characteristics of automatic countdown after preset sampling time, strong resistance overcoming ability, stable and accurate flow rate, small size, light weight, DC power supply, and easy use.
2: YCF-30BMain technical performance:
1. Sampling traffic:
Respiratory dust sampling flow rate: 10-30L/min
2. Working voltage: 12V
3. System negative pressure:>3000Pa
4. Timing range: 0-959 minutes
5. Continuous working time:>100min
6. Usage conditions: -20~40 degrees, relative humidity<85%
7. Dust measurement error:<2%
8. Noise<80dB
9. The respiratory dust particle size symbol BMRC curve, the respiratory dust sampling head does not have the following characteristics for separating particles:
In the formula P=1, P - permeability D - aerodynamic diameter of dust: D0--7.07
10. Weight: 2Kg
11. Sampling range: respiratory dust, total dust
3: YCF-30BInstrument structure principle and calculation formula:
At a flow rate of 20L/min, a certain volume of dusty air is extracted. When passing through the sampling head, coarse dust particles are impacted on an impact plate coated with silicone oil of known mass, while respiratory dust is trapped on a filter membrane of known mass. The mass concentration of total dust and respiratory dust per unit volume of air (mg/m3) is calculated based on the increment of dust on the impact plate and filter membrane after sampling
1. Calculation formula for respiratory dust:
R=(m2-m1)/(Qt)×1000
2. Calculation formula for total dust concentration;
C=(m2-m1)/(Qt)×1000
In the formula: R - respiratory dust concentration, mg/m3
In the formula: C - Calculation formula for dust depth in the air
M1--------- Weight of filter membrane before sampling, mg
M2---------- Weight of filter membrane after sampling, mg
C -- Total dust concentration, mg/m3
Q - Sampling flow rate, 20L/min
T - Sampling time, min
YCF-30BSimilar products include:
serial number |
Instrument name |
model |
Technical Parameters |
price |
71 |
Microbial Air Monitoring Systems |
YCW-2 |
Flow rate 5-35 liters/minute, microcomputer control |
5600 |
72 |
Pocket atmospheric sampler |
TMP-1500 |
Range: 0.1-1.5L/min, timed by computer |
1180 |
73 |
Explosion proof atmospheric sampler |
QC-4 |
Range: 0.1-1.5L/min Timing: 0-99min |
3200 |
74 |
Multi functional dual air path atmospheric sampler |
QCS-3000P |
Digital display of temperature, humidity, and atmospheric pressure Temperature: -25~85 ℃, humidity: 0~100% RH, Atmospheric pressure: 80-110.0 Kp, flow rate: 0.1-1.5L/min |
6200 |
75 |
Dual air path atmospheric sampler |
YCQ-2000 |
Range: 0.1-1.5L/min, microcomputer timing |
2900 |
76 |
dust sampler |
YCF-30D |
Range: 5-30L/min, microcomputer timing |
3800 |
77 |
Individual dust sampler |
YCF-2 |
Range: 0.1-3L/min, electronic timing |
1500 |
78 |
Constant current dust sampler |
DS-31C |
Constant current self-control digital display timing: 1-99 minutes Constant current control: 10-50L/min, maximum: 60L |
4800 |
79 |
Dual channel dust sampler |
YCF-30E |
Dual flow rate: 5-25L/min, microcomputer timing |
4300 |
80 |
YCF-30B |
Total dust, respiratory dust: 5-30L/min |
5800 |
|
81 |
Explosion proof individual dust sampler |
AKFC-92G |
Sampling flow rate: 2L/min, total dust, respiratory dust, continuous working time:>10h, size: 120 × 80 × 42mm |
2900 |
82 |
Mining dust sampler |
AKFC-92A |
Sampling flow rate: 20L/min, continuous working time:>120min, explosion-proof, external dimensions: 200 × 140 × 80mm |
6500 |