SICK sensor from Germany

NegotiableUpdate on 05/25
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

German SICK sensor GL6-N1112 $r $n, our company has * *, we have * * $r $n, if you need a quote, please let me know

Product Details

SICK sensor from GermanyGL6-N1112
Machine modelphotoelectric sensor

working principleMirror reflection photoelectric sensor

Detailed information on working principleDouble lens

Maximum switch distance≤ 6 m 1)

sensing distance≤ 5 m 1)

Polarization filteris

Emit a beam of light

light sourcePinPoint-LED 2)

light source typesVisible red light

Spot size (distance)Ø 8 mm (350 mm)

LED characteristic value

axis length650 nm

settingsNothing

1) Reflector PL80A

2) Average service life: 100000 hours, TU=+25 ° C

Working voltage UB10 V DC . .. 30 V DC 1)

Residual ripple± 10 % 2)

current consumption30 mA 3)

Protection levelIII

digital output

typeNPN

Signal voltage NPN high/low levelApproximately UV/≤ 3 V

Output current Imax≤ 100 mA 4)

response time< 625 µs 5)

switching frequency1,000 Hz 6)

switch typeSwitching between light and dark

Switch type optionalCan be selected through the open/dark switch

protection circuit

A 7)

B 8)

D 9)

1) The critical value for short-circuit protection in the power grid environment is a maximum of 8 A

2) Do not exceed or fall below the UV tolerance

3) No load

4) When Uv>24 V, IA max = 50 mA.

5) Signal transmission time (under resistive load)

6) When the brightness to darkness contrast ratio is 1:1

7) A=UV interface (reverse polarity protection measures have been taken)

8) B=Input and output terminals with reverse polarity protection

9) D=Anti overload current and short circuit protection output terminal

Design and Constructionsquare

Dimensions (width x height x depth)12 mm x 31.5 mm x 21 mm

interfaceCable, 3-core, 2 m 1)

Interface Details

Cross section of wire0.14 mm²

cable length2 m

material

shellPlastic, ABS/PC

Front mirrorPlastic, PMMA

cablePVC

weight60 g

Scope of supplyStainless steel mounting bracket (1.4301/304) BEF-W100-A, reflector P250

1) The wire cannot deform below 0 ° C

Shell protection levelIP67

Operating environment temperature–25 °C . .. +55 °C 1)

Warehouse ambient temperature–40 °C . .. +70 °C

UL file numberNRKH. E348498 & NRKH7.E348498

1) Temperature stability is set at+/-10 ° C

SICK sensor from GermanyGL6-N1112