Rotary fatigue tester

NegotiableUpdate on 05/07
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The rotating rod fatigue tester is an improved version based on similar foreign products and the "Pharmacological Experimental Methodology" rotating rod testing device. It has good practicality and is an ideal instrument for screening and identifying anti fatigue drugs.

Product Details

The rotating rod fatigue tester is an improved version based on similar foreign products and the "Pharmacological Experimental Methodology" rotating rod testing device. It has good practicality and is an ideal instrument for screening and identifying anti fatigue drugs. This instrument can be used for fatigue experiments, exercise coordination ability experiments, skeletal muscle relaxation experiments, central nervous system inhibition experiments, and other experiments that require the use of exercise methods to detect drug effects, such as the impact of toxicity on exercise ability, the impact of a certain substance deficiency in the body on exercise ability, and the impact of cardiovascular and cerebrovascular drugs on exercise ability. The basic principles and functions of this instrument can be developed and utilized in multiple directions.


Rotary fatigue tester

Technical specifications of rotary fatigue tester:

1. Mouse rotor diameter: 30mm, rat rotor diameter: 90mm

2. Mouse rotor length: 62mm, rat rotor length: 90mm

3. Mouse/rat channels: 6 channels

4. Speed range: 1-100 revolutions per revolution

5. Adjustment degree: 1 RPM

6. Speed classification: initial speed, first level acceleration, second level acceleration

7. Initial speed running time: 1~65500 seconds

8. First level acceleration time: 10~65500 seconds

9. First level acceleration duration: 1~65500 seconds

10. Primary speed range: Basic speed~100 revolutions per minute

11. Secondary acceleration time: 10~65500 seconds

12. Second level acceleration duration: 1~65500 seconds

13. Secondary speed range: Primary speed~100 revolutions per minute

14. Equipped with loop mode and forward/reverse mode

15. The number of recording channels can be set from 1 to 6 channels

16. Experimental time range: 1 second to 3000 minutes

17. Internal clock can run for 10 years

18. Hourly error margin ≤ 0.0828 seconds

19. With USB interface, data can be imported into a USB drive

20. Maximum internal storage:>500 sets of data

21. Operating environment temperature: 5 ℃ -40 ℃

22. Input voltage: 110~220V 50Hz

23. Automatic fall photoelectric recording

24. Volume: 620X230X390mm

25. Weight: 16Kg