Roewe Bang Sulfuric Acid Rapid Test Kit Boiler Water Minikit

NegotiableUpdate on 01/09
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The Roewe Bang Rapid Testing Kit for Sulfuric Acid in Boiler Water Minikit uses tablet counting method to quickly test sulfuric acid in boiler water, with a range of 2-50 mg/l NaSO3 and 20-500 mg/l NaSO3.
Product Details

罗威邦 亚硫酸快速测试套装 锅炉水 Minikit

Lovibond®Roewe State, Germany®water quality analysis

LovibondRoewe Bang Sulfuric Acid Rapid Test Kit Boiler Water Minikit


Roewe Bang Sulfuric Acid Rapid Test Kit Boiler Water MinikitRapid testing of sulfite in boiler water using tablet counting method, with a range of 2-50 mg/l NaSO3 and 20-500 mg/l NaSO3.

The Roewe Minikit rapid testing series is suitable for on-site rapid testing, using tablet counting method, titration method, qualitative judgment method, and turbidity method for different chemical properties parameters. Measurable parameters include alkalinity, acidity, hardness, chloride ions, cyanuric acid, nitrite, orthophosphate, quaternary ammonium salt, sulfate, sulfite, sulfur, tannin index, etc.

Order Information

range 2-50 mg/l Na2SO3
Reagent type tablet
test method Tablet counting method
chemical method sulfurous acid
Packaging frequency Approximately 30 times depending on the testing range
Order Number

Low range 414340

High range 414350


Supplementary reagents Sulfite N0.1 per 100 tablets 515270BT

Sulfite LR No.2/100 tablets

515330BT


Instructions for use

Determine the water sample:50ml;

Add 1 N0.1 tablet:Add an N0.1 tablet to the water sample and shake until dissolved;

Add tablet No. 2 until the solution turns blueAdd a No.2 tablet to the water sample, shake until dissolved, observe the color, and then add another No.2 tablet to dissolve until the water sample turns blue. remembernumber of pieces.

Calculate the concentration of nitrous acid

Sulfuric acid mg/lNa2SO3=No.2 tablet quantity x 4-2


For example, taking 50 ml of water sample, adding one tablet of N0.1, and adding five tablets of No. 2, the water sample turns pink blue. Therefore, the concentration of sulfite in the water sample is 5 x 4-2=18 mg/lNa2SO3


Rinse the container thoroughly


Standard Configuration

plastic box

Tablet reagent N0.1 40 tablets, No.2 100 tablets

Container for water samples

Required attachments

Operation Guide