Overview
The BLT-12 resistance strain gauge embedded strain gauge is mainly used for stress-strain measurement in the structural layers of asphalt roadbeds and pavements, as well as for stress-strain monitoring of asphalt in dam black core walls. Can connect dynamic and static strain gauges from various manufacturers to collect data.
Product Details

BLT-12Resistance strain gauge embedded strain gauge

Application scope:

BLT-12Resistance strain gauge embedded strain gaugeUsing highly elastic materials and special processing techniques, high-precision and high-temperature resistant strain gauges are selected as sensitive components. Through processes such as bonding and bridge assembly, they are specially designed and manufactured for the characteristics of high deformation and shear strength of asphalt concrete, high environmental temperature, and strong vibration that can withstand the high temperature and pressure during asphalt pavement construction; This sensor has the advantages of high output sensitivity, good linearity, good stability, high accuracy, and easy installation and use. Mainly used for stress-strain measurement in the structural layers of asphalt roadbeds and pavements, as well as stress-strain monitoring of asphalt in black core walls of dams.connectableCollect data from dynamic and static strain gauges of various manufacturers.

Technical Specifications:

1. Gauge length (L): 120mm

2. Two end blocking components: 6mm diameter and 50mm length threaded steel

3. Range greater than: ± 3000 μ ε

Resolution less than: 1 μ ε

5. Sensitivity coefficient: For example, S=15000 μ ε/mm (strain mode)

S=0.0015mv/μ ε (sensor mode)

6. Bridge resistance: 350 Ω

7. Sensor accuracy: ≤ 0.2% F · S

8. Insulation resistance:>500 M Ω

9. Temperature resistance: within -30 to 80 ℃

10. Wiring method: Red, green, white, and black correspond to+Eg Vi+- Eg Vi -, and the shielded wire is grounded.

Sensor under pressure The data is getting larger, and the sensor is under tension The data becomes smaller.