Residual chlorine controller/transmitter

NegotiableUpdate on 02/14
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The residual chlorine controller/transmitter with pH compensation affects the form of chlorine in water. Reliable residual chlorine measurement must include pH and temperature compensation. Suitable for various occasions where residual chlorine is precisely controlled. Configure a membrane free three electrode residual chlorine electrode for precise measurement. Can be compared to DPD. ● IP65 protection level for the entire machine; Backlight illumination, suitable for harsh usage environments. ● Use integrated switch power modules to further improve the stability and anti-interference ability of the instrument. A concise and clear human-machine interface makes operation more convenient and user-friendly. ● Password protected, important setting parameters will not be modified incorrectly. The set parameters can be browsed in real-time in measurement mode, allowing you to keep track of the working status at any time. Two independently adjustable relays meet the precise control needs of users, with arbitrary delay bandwidth settings. ● Third channel cleaning/alarm function relay: Users can set the cleaning frequency and time themselves. Multiple current output options: 0/4-20mA, with a customizable range for users to record or remotely transmit measurement values. ● Temperature reading offset adjustment: Compare the actual verification values on site to reduce measurement reading errors. RS-485 output

Product Details

pH measurement range 2.00~12.00 pH

resolution 0.01 pH

measurement accuracy ±0.01 pH
Residual chlorine/hypochlorous acid measurement range 0-2000 mg/L or 0-20.00 mg/L

PH compensation range 2.00~9.00 pH

resolution 0.001 mg/L or 0.01 mg/L

measurement accuracy 1%±1***
temperature measurement range -10.0~110.0 °C

resolution 0.1 °C

measurement accuracy ±0.3 °C

temperature input NTC22K / PT1000

temperature compensation automatic
current output output range 4-20 mA (adjustable)

current accuracy 1% FS

Output load Less than 500 Ω
data interface RS485 have
switch control Control method 2 SPST relays

load capacity 2.5A 230 VAC

Cleaning/alarm relay 1X 2.5A
Other parameters working power supply 85-260 VAC or 24 VDC

Operating Temperature 0~60°C

Operating Humidity Relative humidity<90%

Protection level IP65

Installation method Wall-mounted installation

Overall dimensions (H×W×D)158×188×108 mm

weight 0.7 kg