- Phone
-
Address
No. 168 Jianding Road, Cyber Technology Park, Jianggan District, Hangzhou City
Hangzhou Sanpu Precision Instrument Co., Ltd
No. 168 Jianding Road, Cyber Technology Park, Jianggan District, Hangzhou City
Product features of refrigeration, heating, and temperature control system
| model | TEM-125 | TEM-135 | TEM-155 | TEM-175 | TEM-1100 | TEM-1150 |
| TEM-1250 | TEM-1380 | ||
| temperature range | -10℃~+200℃ | ||||||||||
| programmable | 8-stage temperature time program | ||||||||||
| communication protocol | RS 485 interface | ||||||||||
| temperature feedback | Oil outlet temperature and return oil temperature | ||||||||||
| temperature fluctuation | ±0.1℃ | ±0.5℃ | ±0.5℃ | ±0.5℃ | ±0.5℃ | ±0.5℃ | 18KW | 25KW | 38KW | ||
| heating power | 2.5KW | 6KW | 6KW | 9KW | 15KW | 15KW | 18KW | 25kw | 38KW | ||
| cooling capacity
| 200℃ | 2.5KW | 3.5KW | 5.5KW | 7.5KW | 10 KW | 15 KW | 18KW | 25kw | 38KW | |
| 20℃ | 2.5 KW | 3.5 KW | 5.5 KW | 7.5KW | 10 KW | 15 KW | 18KW | 25KW | 38KW | ||
| -5℃ | 1.5 KW | 2.1 KW | 3.3 KW | 4.2 KW | 6 KW | 9 KW | 8KW | 11KW | 17.8KW | ||
| circulation pump | pressure | 2bar | 2bar | 2bar | 2bar | 2.5bar | 2.5bar | 2.5bar | |||
| traffic | 20L/min | 35L/min | 50L/min | 50L/min | 50L/min | 75L/min | 75L/min | ||||
| refrigerant | R-404A | ||||||||||
| interface dimensions | DN15 | DN20 | DN20 | DN20 | DN20 | DN25 | |||||
| power supply | AC220V50HZ | AC380V 50HZ | |||||||||
| Optional one | The temperature range has been expanded to -10℃~+250℃(Add T after model) | ||||||||||
| Option 2 | The temperature range has been expanded to -10℃~+300℃(Add V after model) | ||||||||||
| Optional three | Water cooled type can be selected (with W added after the model) | ||||||||||
safety protection
| Coolant over temperature protection | Compressor high and low pressure protection, overcurrent protection, overheating protection |
| Pipeline overpressure alarm | Water tank refill reminder |
| Pump overload alarm | Automatic exhaust upon startup |