Real time pine wood nematode detector (real-time fluorescence analyzer)

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Quality of one product; Assist in scientific research! POER Smart Real time Pine Wood Nematode Detector

Product Details

POER-Smart96Real time pine wood nematode detector (real-time fluorescence analyzer)


1、 Characteristics and performance requirements

1.1 Control mode: External computer workstation control

1.2 * Openness of reagents and consumables: fully open.

POER-Smart96performance parameters

  • Sample capacity:96×0.2ml

  • Heating and cooling module: using semiconductor mode for heating, the uniformity and stability of the heating module are good

  • *Temperature control technology:6Zone independent temperature control and thermal compensation technology

  • Temperature range: 4-100 ℃

  • Heating rate:5℃/s(MAX)

  • Cooling rate:5℃/s(MAX)

  • Temperature control accuracy: ± 01

  • Reaction system:5ul~120ul

  • *Temperature uniformity: ± 0.2 ℃

  • *Gradient temperature function: equipped with

  • *Gradient temperature region:12

  • Detection component: -20 ℃ cold CCD

  • *Excitation light source: maintenance free wide wavelength tungsten halogen lamp

  • *Number of detection channels:5通道(Scalable)

  • Optional excitation light wavelength range:380-780nm

  • Optional detection light wavelength range:380-780nm

  • Excitation and detection channel medium: bidirectional96 heat-resistant space optical fibers

  • Product size: 550×390×290mm

  • Applicable probes and fuels: FAM/SYBR Green I, VIC/HEX/TET/CY3, ROX/Texas Red, Cy5, TAMARA, etc

  • Software functions: Real time monitoring, automatic discrimination and calculation of positive and negative results, automatic establishment of standard curves, relative quantification, multiple quantification, gene mutation, quality control graphic analysis, fluorescence correction, PCR amplification efficiency, gene typing, gene expression, software * upgrade

  • Working environment temperature: 4-35 ℃

  • Storage temperature: 20 ℃ -55 ℃

  • Relative ambient temperature: 0% -85%

  • Working voltage: 100-240V 50-60Hz