1000AReactor test benchFeatures:
1. Working voltage: three-phase four wire AC380V 50HZ
2Reactor test benchRated capacity 180KVA
3. Rated output current 0-1000A/0-60V * 3
4. Output current accuracy measurement at level 0.5
5. Adopting touch screen+PLC+servo motor (with automatic current stabilization, output current and set current error ≤. 5%)
6. The output current is divided into three levels: 0-50A-500A-1000A, which reduces the error during low current testing
7. Three phase independent adjustable. When measuring a single phase, only one phase's current value needs to be set, and the other two phases can be set to 0
8. Display the output current and voltage of each phase, and automatically convert the voltage/current at both ends of the reactor into the corresponding electrical quantity L=(u0/I) * 2 * 3.14 * f
9. Temperature rise test, equipped with 16 temperature recorders, measurement accuracy ± 0.5 ℃
10. Equipped with 16 K-type 6m temperature probes
11. One set of 5KVA/20KV intelligent testing device for voltage withstand test configuration
12. The current generator adopts forced air cooling
13. Integrated design of the whole machine, equipped with universal tires and brakes at the bottom
14. Appearance 2000 * 900 * 1500mm
15. The total weight of the equipment is 1000kg
1、 The three-phase reactor test bench is a specialized equipment developed and manufactured by our company to test the performance of reactors according to customer needs. The equipment mainly tests the induction withstand voltage and inter turn withstand voltage of reactors.
2、 The technical requirements are as follows: A. Technical parameters Working voltage Three phase four wire AC380V 50HZ Rated capacity 90KVA Rated output current 0-500A/0-50V * 3 Output current accuracy measurement 0.5 level adopts touch screen+PLC+servo motor (with automatic current stabilization, output current and setting current error ≤ (0.5%)) Output current is divided into three levels 0-50A-250A-500A to achieve lower error during small current testing. The three phases are independently adjustable. When measuring a single phase, only one phase current value needs to be set, and the other two phases need to be set to 0 to display the output current and voltage of each phase. The voltage/current at both ends of the reactor is automatically converted into the corresponding electrical quantity L=(u0/I) * 2 * 3.14 * f Temperature rise test, equipped with 16 Road temperature recorder with measurement accuracy of ± 0.5 ℃, equipped with 16 K-type 6m temperature probes for withstand voltage test configuration of 5KVA/20KV The intelligent test device is equipped with a set of current generators that are designed with forced air cooling and integrated into the whole machine. The bottom is equipped with universal wheel and brake equipment with a total weight of 500kg.