QN-801S Single Defense Zone Output Address Module

NegotiableUpdate on 12/01
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The plug-in single zone output alarm module is a zone expansion device with bus communication function, which is very practical for connecting with distant detection devices or in perimeter defense and other occasions; Can be used in conjunction with alarm hosts and other systems; Set switch with address code

Product Details

The plug-in single zone output alarm module is a zone expansion device with bus communication function, which is very practical for connecting with distant detection devices or in perimeter defense and other occasions; Can be used in conjunction with alarm hosts and other systems; Equipped with an address code setting switch. (New generation plug-in wiring, convenient and fast)

1. Specifications and parameters

description Single defense zone with output alarm module
size 5.5 cm x 2.0 cm x 1.0 cm (length x width x thickness)
weight 10 grams
Operating Temperature -10℃ ∽ +50℃; 0-85% humidity
Working Voltage DC 8.5-24V
operating current 20mA
Alarm current 100mA
defensive area Can connect to one normally closed (NC) detection device
output Equipped with a normally open (NO) alarm output, 24V/2A.
Networking function Can be connected to a series of alarm hosts


2. Wiring instructions
Wiring instructions: If connected to a bus, connect the "red" and "black" 8-core wires of "black, yellow, green, red, white, blue, gray, and brown" to the positive and negative terminals of the power supply, respectively. Connect the "green" and "yellow" wires to the 485 bus A (positive) and B (negative), respectively. Connect the "white" and "yellow" wires to the normally closed (NC) and common (COM) alarm outputs of the detection equipment, respectively. Connect the "gray" and "brown" wires to the negative terminals of the power supply and alarm signal.

When used on the same alarm host, each alarm module has its own unique address and cannot have the same address as other alarm modules. Please refer to the installation or user manual of the alarm host for the address range and settings.

3. Indicator light description
● Communication status indicator light description:
1) Constant off: The module power supply is abnormal.
2) Always on: Module communication is abnormal.
3) Flashing: (flashes once per second), module communication is normal.

4. Address coding switch
When connecting the single zone output alarm module to the system for use, it is necessary to encode its address. The encoding is set through the encoding switch, and the address encoding adopts the binary encoding method.
The encoding switches are arranged in the order of "12345678" to set binary addresses.
For example, the code for a certain defense zone expansion module is 11; The corresponding binary number is 00001011, and the order corresponding to the address dip switch is 8-1 (i.e. the high bit is 8 and the low bit is 1). Positions 8, 7, 6, 5, and 3 remain stationary, while positions 1, 2, and 4 are turned to the "ON" side. The address code table is attached.