When the KE-210 purity oxygen analyzer is working, users only need to install the analyzer on the room wall with screws. The instrument contains an oxygen sensor, altitude sensor, atmospheric pressure sensor, temperature sensor, and humidity sensor inside. After the analyzer is powered on and preheated, the required parameters can be read on the LCD screen
KE-210Purity oxygen analyzerat workUsers only need to install the analyzer on the wall of the room with screws. The instrument contains an oxygen sensor, altitude sensor, atmospheric pressure sensor, temperature sensor, and humidity sensor inside. After the analyzer is powered on and preheated, the required parameters can be read on the LCD screen.
Implementation of air purification and deodorization function in the room:
Users can set the cycle period (how long to stop and how long to run) on the analyzer, and the instrument will automatically control the operation of the purification equipment. The purification equipment can also be turned on or off continuously.
Control of oxygen concentration:
Users can freely set the values of the control points on the analyzer (the set values must be greater than the local ambient oxygen concentration), and the instrument controls the valve to change the amount of oxygen entering the room based on the set values, thereby achieving control over the ambient oxygen concentration.
KE-210Purity oxygen analyzerInstrument features:
■Friendly human-machine dialogue menu, intuitive and convenient operation;
■Wall mounted installation, easy and convenient to install;
■Integrated design, compact appearance;
■Modular design, users can choose an altitude measurement module;
■Compared with electrochemistry and ultrasound, it has a longer service life and faster response speed;
■The sensor does not consume electricity, has a long service life, and is easy to maintain;
■No reference gas required, unaffected by the oxygen concentration in the working environment;
■Long calibration interval, high accuracy, stable and reliable;
■High precision temperature automatic compensation system to eliminate the influence of environmental temperature;
■The measurement range is 0~25.0% wide.
Application scope:
Widely used for monitoring oxygen content in various environments such as hospitals, factories, hotels, schools, laboratories, and cold storage.
Technical Specifications:
■Display mode:LCD
■Allowable error:±1% FS
■Repeatability:±1%
■Response time:T90^30s
■ Analog output:
4-20mA DC (non isolated output, load resistance less than 500 ohms)
1 programmable dry contact type passive alarm output, with a large contact capacity of B220VAC/2A
■ Power supply: 18~36V.DC,<5W
■Sample gas temperature: -10 to+50 ° C
■Environmental humidity:<80% RH
■Sampling method: free diffusion
■Sample gas composition: no flammable gas, no corrosive gas, dust content less than 1mg/Nm3
■Specification size: 160mm x 100mm x 130mm (W x H x D)
■Service life:>12 months (under normal usage conditions)
■Installation method: Wall mounted
Optional additional parameters:
■Atmospheric pressure: 30~120KPa
■Environmental temperature: -40 ° C~+85 ° C
■Environmental humidity: 0~100% RH