one、projectorHigh temperature aging roomScope of application, configuration, parameters
Equipment nameProjector high-temperature aging room
1Projector high-temperature aging roomFunction description:
thisAging room is used for high-temperature/room temperature aging of projector products,Maintaining a constant temperature, also known as a constant temperature aging room or projector aging roomCompatible with LCD (with heat dissipation requirements) and DLP (temperature adjustable) products, it can evenly supply and exhaust air, and has the function of self-monitoring over temperature/low temperature alarm, which is convenient for real-time monitoring of product aging status.
2projectorHigh temperature aging roomperformanceindicator:
2.1. Stable range:RT~50℃Adjustable range, temperature control range ± 2 °, compatible with heat dissipation、Constant temperature adjustable,Can evenly supply and exhaust air.
2.2. Aging area:6000mm*5000 mm*2200mm =120m²
2.3. Aging capacity: 3 units * 4 floors * 10 vehicles=120 units
2.4. Aging car size:2150mm*600 mm* 1600 mm
2.5. Product size: 230*230mm*160mm, Distance 410mm
2.6. Power outage alarm: temperature above52℃Perform internal power-off and alarm operation
3. Constant temperature aging roomRequirement:
3.1. Easy to use, compatible with multiple devices, fast to exchange, reliable and durable, with strong maintainability.
3.2. The architectural design of aging houses must comply with national building and safety regulations. The building structure must be stable and reliable, able to withstand the pressure and impact of special environments such as high temperature and high humidity. Buildings should also have safety measures such as fire prevention and leakage prevention.
3.3The constant temperature aging room is installed on site and completedAfter that, the complete set of finished products can be put into use by the first party simply by turning on the power.
3.4Control requirements:
① TheAging ChamberHighly automated constant temperature, reducing or avoiding human intervention and judgment, and lowering learning and operational costs. Employees are only responsible for getting on and off the machine, and temperature changes are determined by software and equipment. Equipped with a temperature display screen, placed outside the aging room, it can visually confirm the internal temperature of the aging room.
② Given the professionalism and specificity of the equipment; Synchronize and attach the complete machine framework diagram, basic function implementation principle summary, and guidance for troubleshooting abnormalities. Leave a USB port for easy copying of aging abnormal logs, daily maintenance on the factory side, and quick location of emergencies.
③ TheallSpecial customized accessories ensure active and traceable maintenance in the future, avoiding any supply issues that may affect the normal use of the equipment.
④ In terms of software configuration, professional core configuration parameters can only be edited by writing them down or with special permissions, and a threshold range explanation should be provided; Basic parameter acquisition is reflected in a pop-up window with a secondary menu, eliminating the need for manual writing in txt format documents and avoiding unnecessary trouble caused by misoperation. Set the lock screen temperature display interface and engineering debugging mode.
⑤ Due to the need for changes in core professional configuration parameters after hardware changes in the product, in order to avoid misoperation, the software body is equipped with functions such as "one click recovery" to facilitate the one click recovery of important preset parameters.
⑥ Test software to set up anti rewrite verification mechanism. Every time the software is opened and run, if any component is missing or damaged, an error message will be prompted with detailed instructions.
⑦ Acceptance of supporting equipment and plans:setting44℃Testing under full load in the aging room3Next, with an interval of 20minIs the temperature at the 9 o'clock position of the venue44±2℃Within the scope.
⑧、The testing software is equipped with an anti rewrite verification mechanism. Every time the software is opened and run, if any component is missing or damaged, an error message will be displayed with detailed instructions.
twoTop view reference diagram of constant temperature aging room

three、Constant temperature aging roomTraining requirements
1. Operation training.
2. Training on common troubleshooting.
3. Daily maintenance training.
4. The training period shall not be less than 2 working days (starting from the handover and trial production of the equipment after commissioning at the factory).
four、High temperature aging roomAfter-sales service
1. The second party is responsible for going to the first party's location forConstant temperature aging roomThe installation and debugging costs incurred shall be borne by Party B.
2. If any of the performance and standard requirements of Party B's equipment are not met, Party A has the right to handle the return.
3. The second party shall provide a list of vulnerable parts of the equipment and corresponding prices.
4. Provided by Party BConstant temperature aging roomWarranty according to the agreed time in the contract, lifelong maintenance. During the warranty period, all spare parts of the equipment that are not damaged by human factors shall be replaced free of charge. In the event of a malfunction, Party A shall notify Party B and arrive at the site within 12 hours to replace and repair them free of charge. If a serious malfunction occurs, maintenance personnel must be in place within 4 hours from notification.
5. After the equipment is out of warranty, Party B shall not charge on-site fees or labor fees for repairing the equipment for Party A. Only accessory fees shall be charged, and Party B shall ensure that the price of the original factory accessories is equal to or lower than the manufacturer's unified price.
6After the installation of the constant temperature aging room is completed,Free equipment operation training, application software training, and training on operating instructions and precautions related to equipment use.