Precision constant temperature water bath

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

LD-RT series precision constant temperature water bath uses a temperature range of+5~100 ℃ for ambient temperature, with a constant temperature accuracy of 0.02 ℃. Application areas: Widely used in thermocouples, thermistors, chemical engineering, petroleum, medicine, physics, metrology, universities, electronic instruments, scientific research institutions, and other fields

Product Details

Precision constant temperature water bathDesign features:

♦The inner liner is made of all stainless steelSUS304;The shell is made of stainless steel plate with hairline pattern, which looks like new even after many years of use and will not rust!

♦ circuit boardDesign adoptsSMTAssembly technology, precision constant temperature control system adoptsPIDIntelligent program control enables accurate temperature control across the entire range,0.01℃The high-resolution temperature control instrument can control the fluctuation of water temperature within≤±0.05℃;0.1℃The temperature control instrument with high resolution can control the fluctuation of water temperature within≤±0.5℃.

♦ high trafficInternal circulation ensures temperature uniformity and is mainly used for testing samples or containers placed in tanks. The internal circulation type has a larger flow rate than the external circulation type, and the water temperature will be more uniform; The external circulation constant temperature water tank is mainly used to connect with external equipment through a circulation hose, and continuously circulate hot water to maintain high temperature and constant temperature on external equipment or container jackets. Due to the large heat dissipation during external circulation, the accuracy is relatively lower compared to internal circulation. So users should pay attention to the difference in this item when selecting, and choose the appropriate product according to their own usage needs.

♦The internal circulation adopts isolated centrifugal blades for stirring, resulting in a uniform temperature field and greatly improving temperature control accuracy and uniformity.

♦It has functions such as overcurrent protection, safety grounding, digital temperature correction, sensor open circuit and short circuit alarm, over temperature alarm, and automatic recovery after power outage, greatly improving work efficiency.

♦Use power supplyAC 220V 50HZ 0.2~2.5KWUnequal configuration.


Precision constant temperature water bathModel and parameters:

model

temperature range℃

temperature fluctuation℃

Size inside the groove (Long)*wide*deepmm)

Groove depthmm

Slot sizemm

Overall dimensionsmm

cycle mode

LD-RT-1A

room temperature+5~100

±0.05

130*60*150

150

130*60

330*220*360

internal circulation

LD-RT-1B

room temperature+5~100

±0.5

LD-RT-2A

room temperature+5~100

±0.05

130*120*150

150

125*120

330*280*360

internal circulation

LD-RT-2B

room temperature+5~100

±0.5

LD-RT-5A

room temperature+5~100

±0.05

250*150*150

150

245*150

450*310*360

internal circulation

LD-RT-5B

room temperature+5~100

±0.5

internal circulation

LD-RT-5C

room temperature+5~100

±0.5

External circulation flow rate4L/min

LD-RT-10A

room temperature+5~100

±0.05

280*190*200

200

275*190

480*350*390

internal circulation

LD-RT-10B

room temperature+5~100

±0.5

internal circulation

LD-RT-10C

room temperature+5~100

±0.5

External circulation flow rate4L/min

LD-RT-15A

room temperature+5~100

±0.05

280*250*200

200

275*250

480*410*390

internal circulation

LD-RT-15B

room temperature+5~100

±0.5

internal circulation

LD-RT-15C

room temperature+5~100

±0.5

External circulation flow rate4L/min

LD-RT-18A

room temperature+5~100

±0.05

320*280*200

200

315*280

520*440*390

internal circulation

LD-RT-18B

room temperature+5~100

±0.5

internal circulation

LD-RT-18C

room temperature+5~100

±0.5

External circulation flow rate4L/min

LD-RT-25A

room temperature+5~100

±0.05

280*250*300

300

275*250

480*410*490

internal circulation

LD-RT-25B

room temperature+5~100

±0.5

internal circulation

LD-RT-25C

room temperature+5~100

±0.5

External circulation flow rate4L/min

LD-RT-30A

room temperature+5~100

±0.05

400*330*230

230

395*330

600*490*420

internal circulation

LD-RT-30B

room temperature+5~100

±0.5

internal circulation

LD-RT-30C

room temperature+5~100

±0.5

External circulation flow rate4L/min

If the above parameters do not meet your usage requirements, the company can also customize according to your needs. Standard products will be shipped on the second day after factory testing, and non-standard products will be shipped on the third day. For non-standard customization, please contact our Mr. Zhang