Welcome Customer !

Membership

Help

Nanjing Hengxing Experimental Equipment Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products
Product Categories

Nanjing Hengxing Experimental Equipment Co., Ltd

  • E-mail

  • Phone

  • Address

    No. 109 Lanhua Road, Qiaolin Economic Development Zone, Pukou District, Nanjing

Contact Now

Precision constant temperature water bath

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Temperature range of precision constant temperature water bath: ambient temperature~100 ℃; Constant temperature accuracy is optional. Widely used in scientific research institutions such as metrology, petroleum, biology, medicine, chemical engineering, electronics, materials, and universities, providing precise constant temperature water bath temperature fields. If the above parameters do not meet your usage requirements, our company can also design according to your needs.

Product Details

  Precision constant temperature water bathDesign features:
♦ This water tank has an inner liner made of all stainless steel SUS304; The shell is made of hairline stainless steel plate, which looks like new even after years of use!
♦ A precision constant temperature control system designed independently using PLC programming technology, with PID intelligent program control, enables precise temperature control over the entire range. The high-resolution 0.01 ℃ temperature control instrument can accurately control water temperature fluctuations within ≤± 0.05 ℃; A temperature control instrument with a resolution of 0.1 ℃ can control the fluctuation of water temperature within ≤± 0.5 ℃. The temperature can be manually and automatically calibrated.
♦ The internal circulation type high-temperature constant temperature water tank is mainly used for testing the test sample or container in the tank. The internal circulation type has a larger circulation flow rate and a more uniform water temperature than the external circulation type; The external circulation constant temperature water tank is mainly used to connect with external equipment through a circulation hose, and continuously circulate hot water to maintain high temperature and constant temperature on external equipment or container jackets. Due to the large heat dissipation during external circulation, the accuracy is relatively lower compared to internal circulation. So users should pay attention to the difference in this item when selecting, and choose the product according to their own usage needs.
♦ The internal circulation of the constant temperature water tank adopts isolated centrifugal blades for stirring, resulting in a uniform temperature field and greatly improving temperature control accuracy and uniformity.
♦ It has functions such as overcurrent protection, safety grounding, digital temperature correction, sensor open circuit and short circuit alarm, over temperature alarm, and automatic recovery after power outage, greatly improving work efficiency.
♦ The configuration of using power supply AC 220V 50HZ 0.2~2.5KW varies

Precision constant temperature water bathModel and parameters:

model

temperature range

temperature fluctuation

Size inside the groove(Length * Width * Depth mm)

Groove depthmm

Slot size mm

Overall dimensions mm

cycle mode

LD-RT-1A

room temperature+5~100

±0.05

130*60*150

150

130*60

330*220*360

internal circulation

LD-RT-1B

room temperature+5~100

±0.5

LD-RT-2A

room temperature+5~100

±0.05

130*120*150

150

125*120

330*280*360

internal circulation

LD-RT-2B

room temperature+5~100

±0.5

LD-RT-5A

room temperature+5~100

±0.05

250*150*150

150

245*150

450*310*360

internal circulation

LD-RT-5B

room temperature+5~100

±0.5

internal circulation

LD-RT-5C

room temperature+5~100

±0.5

External circulation flow rate4L/min

LD-RT-10A

room temperature+5~100

±0.05

280*190*200

200

275*190

480*350*390

internal circulation

LD-RT-10B

room temperature+5~100

±0.5

internal circulation

LD-RT-10C

room temperature+5~100

±0.5

External circulation flow rate4L/min

LD-RT-15A

room temperature+5~100

±0.05

280*250*200

200

275*250

480*410*390

internal circulation

LD-RT-15B

room temperature+5~100

±0.5

internal circulation

LD-RT-15C

room temperature+5~100

±0.5

External circulation flow rate4L/min

LD-RT-18A

room temperature+5~100

±0.05

320*280*200

200

315*280

520*440*390

internal circulation

LD-RT-18B

room temperature+5~100

±0.5

internal circulation

LD-RT-18C

room temperature+5~100

±0.5

External circulation flow rate4L/min

LD-RT-25A

room temperature+5~100

±0.05

280*250*300

300

275*250

480*410*490

internal circulation

LD-RT-25B

room temperature+5~100

±0.5

internal circulation

LD-RT-25C

room temperature+5~100

±0.5

External circulation flow rate4L/min

LD-RT-30A

room temperature+5~100

±0.05

400*330*230

230

395*330

600*490*420

internal circulation

LD-RT-30B

room temperature+5~100

±0.5

internal circulation

LD-RT-30C

room temperature+5~100

±0.5

External circulation flow rate4L/min

If the above parameters do not meet your usage requirements, the company can also customize according to your needs. Standard products will be shipped the next day after factory testing, while non-standard products will be shippedShipment on the third day. Non standard customization: Mr. Zhang