Welcome Customer !

Membership

Help

Beijing Aotesipu Technology Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Precision air conditioning professional water softener

NegotiableUpdate on 07/28
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The precision air conditioning professional water softener series fully automatic water softener adopts the FLECK fully automatic softening control valve from PENTAIR Group in the United States. And assembled with high-quality fiberglass resin tanks. Precision air conditioning professional water softener

Product Details

Brief Introduction

The precision air conditioning professional water softener series fully automatic water softener adopts the FLECK fully automatic softening control valve from PENTAIR Group in the United States. And assembled with high-quality fiberglass resin tanks. Precision air conditioning professional water softener


Precision air conditioning professional water softener Detailed Introduction
Precision air conditioning professional water softener

Requirements for the use of soft water systems
1. Inlet pressure: 0.2Mpa-0.6Mpa;
2. Residual hardness: ≤ 0.03mmol/L; Raw water hardness (calculated as 1/2Ca2+, 1/2Mg2+): ≤ 10.0mmol/L;
(Calculated as 1/2Ca2+, 1/2Mg2+)
3. Power supply: AC220V, 50Hz, 6W-50W;
4. Working temperature: 2 ℃ -50 ℃;
5. Reclaimed water consumption: 3% -5% * cycle water production volume;
6. The equipment outlet should be designed with a water storage tank and equipped with a water level control device;
7. There are drainage facilities near the equipment (* not exceeding 3 meters);
8. When the raw water quality meets the municipal tap water standards, normal selection can be made. If the water quality is unknown or untreated underground, a national water quality report is required, and our company can design a separate one for the customer;
9. The processing capacity of a single set of fully automatic water softening equipment ranges from 0.5T/H to 150T/H. For models not listed in the table, please contact the company's engineering technology department directly.
【 Application Fields 】
Suitable for humidifying equipment in communication rooms, precision air conditioning in switch rooms, air conditioning in network rooms, offices, computer rooms, archives rooms, gyms, reading rooms, electronic archives rooms, hotels, high-end office buildings, cinemas, art galleries, banks, museums, electrical and electronic precision processing workshops, etc. The series of fully automatic water softeners adopts the FLECK fully automatic softening control valve from PENTAIR Group in the United States. And assembled with high-quality fiberglass resin tanks. The entire equipment has the characteristics of high automation, small footprint, fast operation speed, stable effluent quality, strong corrosion resistance, and long service life.
Main features and functions of fully automatic water softener
■ Water production - When water containing calcium and magnesium ions (Ca2+, Mg2+) flows through a resin layer at a certain pressure and flow rate, the binding ability between calcium and magnesium ions (Ca2+, Mg2+) and the resin is greater than that between sodium ions (Na+) and the resin. Therefore, the calcium and magnesium ions (Ca2+, Mg2+) in the water exchange with the sodium ions (Na+) on the resin, and the calcium and magnesium ions (Ca2+, Mg2+) are adsorbed by the resin. In this way, the water flowing out of the resin layer no longer contains calcium and magnesium ions (Ca2+, Mg2+). 2RNa++Ca2+(Mg2+) ← Water production → Regeneration of R2Ca2+(Mg2+)+2Na+
Regeneration - When the sodium ions (Na+) on the resin are exchanged by the calcium and magnesium ions (Ca2+, Mg2+) in the water, the resin loses its exchange capacity and must be regenerated with salt water. The regeneration process mainly includes: backwashing, saline suction, slow flushing (replacement), fast flushing (positive flushing), saline re injection and other processes.
■ Backwash - After regeneration begins, use water to backwash the resin from bottom to top. Its purpose is to loosen the resin layer compacted in the water making process, which is conducive to the full contact between the resin particles and the salt solution, making the regeneration more thorough; 2. Suspended solids accumulated on the resin surface during the water production process.
■ Saltwater suction - Saltwater enters the resin tank from the salt tank through the "jet salt suction device" with a fully automatic control valve.
Slow flushing (displacement) - High concentration sodium ions (Na+) in saline exchange with calcium and magnesium ions (Ca2+, Mg2+) on the resin. After the calcium and magnesium ions (Ca2+, Mg2+) are exchanged, they are discharged with water. The sodium ions (Na+) in saline are adsorbed by the resin, and the resin regains its exchange capacity.
■ Quick wash (positive wash) - The purpose of quick wash (positive wash) is to remove residual salt solution in the resin layer and reduce chloride ions (Cl -).
■ Salt water re injection - During regeneration, the salt water in the salt tank is completely absorbed. Therefore, after regeneration, the water flow is controlled by a fully automatic control valve, and the salt tank is re injected with clean water to ensure the next regeneration use.

model
Import and export pipe diameter (inches)
Processing water volume T/H
Resin tank
mm
Salt bucket size
XHmm
Resin quantity
kg
cover an area
L×W×Hm
notes
5600A
1
1
250*1400
300*600
40
1*0.5*2
Single head single can
5600B
1
2
300*1650
400*800
60
1.1*0.6*2
Single head single can
5000T
1
2-4
400*1650
400*800
100
1.2*0.7*2
Single head single can
2750
1
5-6
500*1750
520*1030
180
1.5*0.8*2.2
Single head single can
2850
1.5
6-12
600*1850
650*1080
260
1.7*1*2.4
Single head single can
2900/4A
2
10-15
900*2200
860*1080
560
2.2*1.2*3
Single head single can
2900/4B
2
15-20
1000*2200
1080*1350
760
2.5*1.3*3
Single head single can
3900/4A
3
20-30
1200*2400
1080*1350
1000
2.7*1.5*3.5
Single head single can
3900/4B
3
30-40
1500*2400
1080*1350
1500
3*1.8*3.5
Single head single can
8500
1
1-2
250*1400
400*850
120
2*0.5*2
Single head single can
9000A
1
2-3
300*1610
400*850
120
2.0*0.7*2
Single head double can
9000B
1
3-5
400*1610
520*1030
200
2.2*0.7*2
Single head double can
9500A
1.5
5-7
500*1750
520*1030
360
2.5*0.8*2.2
Single head double can
9500B
1.5
8-12
600*1850
650*1080
520
2.6*1*2.4
Single head double can
2850/7
1.5
6-12
600*1850
650*1080
520
2.6*1*2.4
One backup, one use
2900/7A
2
15
900*2200
860*1080
1120
4.2*1.2*3
One backup, one use
2900/7B
2
20
1000*2200
1080*1350
1500
4.5*1.3*3
One backup, one use
3900/7A
3
40
1200*2400
1080*1350
2400
6*1.5*3.5
One backup, one use
3900/7B
3
50
1500*2400
1080*1350
3200
6.5*1.8*3.5
One backup, one use
2900/6A
2
30
900*2200
860*1080
1120
4.2*1.2*3
Working simultaneously
2900/6B
2
35
1000*2200
1080*1350
1500
4.5*1.3*3
Working simultaneously
3900/6
3
60-80
1500*2400
1080*1350
3200
6.5*1.8*3.5
Working simultaneously