The 910.21 model pre volume flame arrester allows the installation of pressure measuring instruments and diaphragm sealing systems in areas required by EPL Ga (Zone 0).
The 910.21 model is cleverly connected to factory measuring instruments to form a measuring device. Pre volume flame arresters not only allow liquid flow, but also effectively prevent flames from spreading from the instrument side (unprotected side) to the process side (protected side) in the event of a malfunction.
The pre volume explosion-proof flame arrester is an integrated factory design, suitable for Ex certified pressure gauges and diaphragm sealing systems equipped with Ex certified measuring instruments.
The 910.21 model meets the requirements of the flame arrester coordination standard EN ISO 16852.
Has passed ATEX and IECEx certification, meeting European and international explosion-proof safety requirements.