- Phone
-
Address
Jinbolong Industrial Zone, No.1 Huayun Road, Yucui Community, Longhua Street, Longhua District, Shenzhen City
Shenzhen Iris Instrument Co., Ltd
Jinbolong Industrial Zone, No.1 Huayun Road, Yucui Community, Longhua Street, Longhua District, Shenzhen City
Shenzhen Iris Instrument ARS-SF100Potassium chloride KCL powder moisture rapid analyzerIt is a fully automatic rapid moisture analyzer with a precision of one ten thousandth. Its accuracy reaches 0.0001g (0.1mg, one ten thousandth accuracy), and the accuracy of the measured sample moisture content can reach 0.001% (10PPM moisture content). The testing speed is fast and the results are accurate. Parameters and conditions can be set directly through the 7-inch touch LCD screen, achieving human-machine integration operation, and having the function of connecting with computers and printers. Generally, the product can measure the results in a few minutes and automatically lock the final value, without the need for personnel supervision. The results are accurate and consistent with the oven experiment, greatly reducing the operator's time. The testing principle of the Iris rapid moisture analyzer meets GB/T29249-2012 electronic weighing drying method moisture analyzer.
Instrument Features
The 7-inch LCD screen is clearer and brighter, and provides rich measurement information.
Convenient touch button operation, one click testing, easy to operate.
Outstanding performance is achieved through the use of insulated weighing sensor technology, which prevents the accuracy of symmetrical measurements from being affected during the heating process.
Standard RS232 interface for easy connection to printers, computers, and other peripheral devices.
Infrared heating heats up quickly, greatly reducing the time required for testing.
Real time display of moisture, weight, and time for easy monitoring of testing progress.

ARS-SF100Potassium chloride KCL powder moisture rapid analyzertechnical parameters
Working principle: Determine the moisture content of the sample using the heating weight loss method
Product Usage: Specially suitable for high-tech enterprises, universities, research institutions, laboratories with high requirements, and determination of trace moisture
Application areas: Plastics, pharmaceuticals, chemicals, batteries, minerals, and other industries that require rapid and accurate detection of moisture content
最大称量 :110g
Accuracy: (0.1mg, accuracy of one ten thousandth)
Moisture range: 0.000%~100.000% (moisture content)
Dry weight range: 100.000%~0.000% (including solid content)
Interface language: bilingual system switching between Chinese and English
Sensor: Electromagnetic force sensor
Display mode: 7-inch high-definition touch screen operation; Large LCD screen display
Management permissions: Administrator permissions function, which allows setting login passwords for administrators and operators.
Opening the cabin door: automatic heating cabin door function, dual drive motor electric door opening and closing system; Intelligent sensing function
Instrument calibration: single point calibration, three-point and one line calibration (external calibration)
Environmental calibration: used to deduct the influence of moisture on the experimental results in a damp environment on the scale pan
Sample weight setting: The upper and lower limit weights of the test sample can be set
Minimum weight: 0.0004g
Moisture readability accuracy: 0.001% (moisture content)
Dry weight readability accuracy: 0.001% (including solid content)
Repeatability: allowed ≤ 3d; sample weight ≥ 1g, ± 0.1%; Sample weight ≥ 5g, ± 0.02%
Test temperature: 40~230 ℃, 1 ℃ step
Curve display: Real time drying curve provides a visual representation of the entire moisture process
Sample visualization: Transparent heating window for real-time observation of sample changes
Information settings: company name, company address, contact information, product name, input
Scale pan size: diameter 100mm
Operating temperature: 5-35 ℃ ambient temperature
Heating modes: standard heating, fast heating, gentle heating, step heating
Shutdown modes: automatic shutdown, manual shutdown, timed shutdown, custom shutdown
Heating method: halogen lamp efficient heating
Baud rate: set to 1200/2400/4800/9600 (optional)
Output interface: standard RS232 interface, optional USB interface
Storage data: 200 sets of program settings addresses; 200 sets of historical test records, available for viewing and printing; Compliant with GLP standards
Display parameters: heating mode, shutdown mode, test temperature, test time, moisture content, solid content, moisture content, dry weight
Other functions:
1. Sample name/company/communication information input
2. Login with administrator/operator password permission
3. Time and date, historical test database
4. Optional Bluetooth WIFI
5. Printing settings for various specifications of label paper
6. Temperature calibration
7. No need for samples, one click empty disk preheating
8. Ultra quiet fan
9. Dual drive motor automatic door opening system