YGROPALM HP32 handheld temperature and humidity meter
Technical Specifications
compatibility
All HC2 and HC2A sensors
HW4 software>V3.9
packaging
HygroPalm HP32 (sensorless)
Nylon bag
USB data cable (for computer connection and battery charging)
HW4 LITE authorization code (Z connects 3 instruments)
Overview
Instrument type: Handheld meter (% RH/° C)
Compatible sensors: all HC2A and HC2 sensors
Measurement range: -10... 60 ° C | 0... 100% RH (non condensing, non condensing)
Storage range: -10... 45 ° C | 10... 90% RH
Sensor measurement range: depends on the sensor
Accuracy: depends on the sensor
function
On site measurement editable interval (Z small on-site measurement editable interval)
Record interval: 1 second... 24 hours
Storage capacity: 8 x 8000 data strips
Humidity calculation value:
Dew point/frost point (Dp/Fp)
Wet bulb temperature (Tw) (Tw) (Tw) (Tw)
Enthalpy (H) (H) (H)
J for humidity (Dv)
Water vapor content (Q)
Mixing ratio (R)
Partial pressure of water vapor (E)
Water vapor saturation pressure (Ew)
Saturated vapor density (SVD)
Calculation method: WMO standard
Display refresh rate Display refresh rate: 1 second (under normal circumstances) (under normal circumstances)
Battery: Lithium battery, 3.7 V, 1000 mAh
48 hours - Record once every 30 seconds, turn off screen record once, turn off screen record once, turn off screen record once, turn off screen record once
10 hours - Screen always on Screen always on
PC interface: USBUSBUSB interface, compatible interface, compatible with HW4 software>V3.9 shell/mechanical parameters
Shell material: ABS, TPR
Protection level: IP65
Size: 160 x 63 x 30 mm
Weight: 185 grams
HP32P32P32 optional sensor
Standard sensors and high-precision sensors
Accuracy (Standard Version): Accuracy (Standard Version): Accuracy (Standard Version): Accuracy (Standard Version): ± 0.8% RH, ± 0.1 K (10... 30 ° C)
Precision (High Version): Precision (High Version): Precision (High Version): Precision (High Version): ± 0.5% RH (10... 90% RH), ± 0.1 K (10... 30 ° C)
Measurement range: -50... 100 ° C, 0... 100% RH
Long term stability:<1% RH/year
Order number: HC2A-S (Standard Edition), HC2A-SH (High Precision Edition) (High Precision Edition) (High Precision Edition)
High temperature handheld sensor
精度: ±0.8 %RH, ±0.2 K(10...30 °C)
Measurement range: -100... 200 ° C, 0... 100% RH
Long term stability:<1% RH/year
Cable length: 2m
Order number: HC2-HK25
Plug in sensor
精度: ±0.8/1.5 %RH, ±0.1/0.3 K ( 10…30 °C)
Measurement range: -40... 85 ° C/0... 100% RH
Long term stability:<1% RH/year
Cable length: 2m