Portable micro pressure calibratorDetailed information:

MY-GJ100-H6WQ Portable Micro Pressure Calibration InstrumentSuitable for various models of micro pressure calibrators using pressure sensing elements as detection probes for inspection, standard use. It is a calibration standard calibration instrument designed for the poor production conditions in pharmaceutical factories and coal mines, where the micro pressure calibration instrument is severely damaged during on-site use and requires frequent inspection standards.
Portable micro pressure calibratorIt is a clever standard calibration instrument for on-site pressure calibration and measurement in departments such as power, petroleum, chemical, metallurgy, plastics, papermaking, medicine, food, and environmental protection. It has stable output pressure and high precision adjustment (small adjustment of 1Pa), and is used for performance testing and calibration of pressure instruments in various pressure detection departments.
Portable micro pressure calibratorFeatures:
2.1 Volumetric pressure design with good air tightness performance.
2.2 Fine micro pressure adjustment function ensures long stable output pressure time and reduces pressure signal fluctuations caused by pressure inertia.
2.3 There are two adjustment methods, coarse and fine, which greatly achieve the pressure at the calibration point.
2.4 Portable box packaging, small in size, light in weight, easy to operate, and convenient to carry.
Main technical specifications of intelligent micro differential pressure calibrator
4.1 Pressure range: -6~6kPa, -4~4kPa, -10~10kPa, -20~20kPa, ± 30kpa, ± 40kPa, ± 60kPa, ± 100kpa, 0-160kPa, 0-250kPa. For more ranges, please contact customer service.
4.2 Adjustment details: min 0.1Pa
4.3 Medium: Pure air
4.4 Dimensions: 325 * 220 * 230
4.5 Weight:<6kg
4.6 Pressure: Accuracy 0.1% FS, 0.05% FS Current: Accuracy 0.05% FS,
4.7 Overload pressure: 1.5 times full range
4.8 Current measurement: 0-22mA
4.9 Output power supply: DC24V
Operation of portable micro pressure calibrator
1、power supplykey:presspower supplyKeymetertableelectricitySource Strikeopen, And then selfDynamic conversiontomeasureQuantitative formstate;Press againpower supplykey,ceremonytablecloseMachine, cut offelectricitySource.
2TheSWTCH TEST/MAX/MINkey:forSelect the pressure switch test recording function or the maximum and minimum value recording function.
3TheVkey:forchoice± 50V DCVoltage measurementQuantity.
4ThemAkey:forchoice± 25mA DCelectricityflowmeasureQuantity.
5ThePressurekey:Used for selecting pressure measurement operations, when the instrument is equipped with multiple pressure modules, it is used to select the pressure module range.
6、ZEROkey:zero adjustmentkey, measurePress once before measuringZEROkey, ceremonyWithin the tableCPUenterRow zero pointplaceLi, BaoProof testingAccurate quantitative data.
7key:forCorrectplaceselectoperationitemindeedrecognizeWhen the lightMark locationYupress力measurequantityItem timethatThe key is pressed力singlebitchoice, heavyagainpressThis keycan bePSITheinH20TheinHgThembarThebarThemmH2O、mH2Or 、 mmHgThemHgThekgf/cm2ThePa (KPa)ThekPa (MPa)ofintervalfollowringCutchange.
8key:Backlight button, used to turn on the instrument panel backlight when illuminatedMark locationYupress力apparentDisplay Areatime, used forSelection pressure力5Position or6bitapparentshowWhen calibration is requiredtime,Choose wellcalibrationCorrectelephant(voltage, current or pressure),longPress this key3secondenterAdmission Permitstate. Press Key selectioncalibrationitem:fullRange calibration(screenapparentshowFS Cal)Then pressZERO keyEliminate zero point error(Absolute pressure zero point is 10kPa), addfullPress after measuring range keyindeedrecognize, ScreenapparentDisplay calibration prompt for temperature indication location:apparentshow' E0 'Indicates successful calibration,apparentshow'E1'expressgivefixedvalueandfulldegreevalueDeviation exceedspass5/100,apparentshow' E2'Indicates communication lossdefeatIf calibration is lostdefeat,Pleaseaccording toerrorhintcheckRe calibrate afterwards. The positive and negative pressure ranges need to be calibrated separately for the full range of positive and negative pressure.After the calibration steps are completed, the test can be carried out according to the normal steps. Before testing, press theZERO Zero School.
9、Detecting changesDelivery device:ceremonyTable equipped with24VDCelectricitySource.Detecting changesDelivery devicetime, directlyceremonyDon't hit meopentoelectricityflowmeasurement functionFollow the wiring instructions on the instrument panel andchangeConnect the transmitter, that's itDetecting changesDelivery performance.
10overrangereportpolice:thisceremonyThe table has an over rangereportPolice function, When addedpressForce exceedsuhfixedfullA certain range of measurementtime,ceremonyTable willFlashing displayDisplay and embed beeschirpThe device will be brokensubsequent issuanceSound representspressPower orvoltage(electricityflow)exceedfullCheng, thisWhen shouldStop addingpressAnd remove some partspressForce makes it inruleWithin the quantitative range, to avoiddamagebadpress力biographySensors.
Attachment: Range selection (special ranges can be customized)
range |
Accuracy (F • S) |
range |
Accuracy (F • S) |
||
-100~100KPa |
0.05% |
0.02% |
0~600KPa |
0.05% |
0.02% |
-60~60KPa |
0.05% |
0.02% |
0~1MPa |
0.05% |
0.02% |
-25~25KPa |
0.05% |
0.02% |
0~1.6MPa |
0.05% |
0.02% |
-10~10KPa |
0.05% |
0.02% |
0~2MPa |
0.05% |
0.02% |
-6~6KPa |
0.05% |
0.02% |
0~2.5MPa |
0.05% |
0.02% |
-4~4KPa |
0.05% |
0.02% |
0~4MPa |
0.05% |
0.02% |
0~25KPa |
0.05% |
0.02% |
0~6MPa |
0.05% |
0.02% |
0~40KPa |
0.05% |
0.02% |
0~10MPa |
0.05% |
0.02% |
0~60KPa |
0.05% |
0.02% |
0~16MPa |
0.05% |
0.02% |
0~100KPa |
0.05% |
0.02% |
0~25MPa |
0.05% |
0.02% |
0~160KPa |
0.05% |
0.02% |
0~35MPa |
0.05% |
0.02% |
0~250KPa |
0.05% |
0.02% |
0~40MPa |
0.05% |
0.02% |
0~400KPa |
0.05% |
0.02% |
0~60MPa |
0.05% |
0.02% |