The F-940 portable ethylene analyzer detects ripening gases during storage to increase the shelf life of food and prevent food spoilage, ensuring food quality.
|
![]() |
||||||||
major function |
|||||||||
|
Ø Measure response time:< 30 s Ø Historical measurement data can be accessed at any time Ø Handheld design, compact and lightweight Ø 4GSD card stores data Ø Bluetooth data transmission Ø Battery life: 8h Ø High definition LCD screen, visible under light Ø PolarCept!TMElectrochemical induction technology |
![]() |
||||||||
| Measurement parameters | |||||||||
| Ethylene, carbon dioxide, and oxygen concentrations, date, time, humidity, temperature, GPS positioning data | |||||||||
| application area | |||||||||
|
Ø Environmental control management of storage facilities Ø Ethylene emission reduction verification Ø Inspection of food processing plants Ø Accurate judgment of citrus ripening Ø Storage allocation in distribution centers Ø Quality assurance of modified atmosphere preservation packaging |
|||||||||
Main technical parameters |
|||||||||
|
Ø Intake speed: 70 mL/min Ø Data storage: automatically saved every 1 second, capable of storing tens of thousands of sets of data Ø Display: Visible LCD screen under light Ø Operating environment: 0-45 ℃ (relative humidity 0-90%, no dew point) Ø Size: 18cm × 13.5cm × 5.5cm Ø Weight: 0.95kg Ø Shell: Aluminum alloy shell Ø Power supply: portable, rechargeable battery Ø Computer interface: USB interface and SD card Ø Data recording: C2H4Concentration CO2Concentration O2Concentration, date, time, relative humidity, GPS data |
|||||||||
| Ethylene sensor | |||||||||
|
Ø Sensor type: Electrochemical detector Ø Measurement range: 0-10ppm Ø Resolution: 0.1ppm Ø Accuracy: ± 3% relative, ± 0.15% absolute measurement value Ø Minimum detection limit: 0.1ppm Ø Zero point calibration: daily Ø Span calibration: 3 months Ø Service life: 12 months |
|||||||||
| CO2 sensor | |||||||||
|
Ø Sensor type: Infrared thermoelectric sensor Ø Measurement range: 0-100% Ø Resolution: 0.01% absolute concentration Ø Accuracy: ± 1% absolute concentration, ± 3% measured value Ø Air intake time: 10 seconds Ø Calibration: Annual Ø Service life:>5 years |
|||||||||
O2sensor |
|||||||||
|
Ø Sensor type: Electrochemical detector Ø Measurement range: 0-100% Ø Resolution: 0.1% absolute concentration Ø Accuracy: ± 0.25% absolute concentration, ± 2% measured value Ø Air intake time: 10 seconds Ø Calibration: 2 years Ø Service life: 12 months |
|||||||||
| Purchase Guide | |||||||||
|
Host, manual, related accessories, box |
|||||||||
![]() |
![]() |
||||||||
| Place of Origin: Felix from the United States | |||||||||