Portable AC/DC dual-purpose atmospheric sampler

NegotiableUpdate on 05/07
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Scope of application: Yuntang portable AC/DC dual-use atmospheric sampler uses solution absorption method to collect various harmful gases in environmental atmosphere and indoor air; The filter membrane weighing method is used to capture total suspended particles (TSP) and inhalable particles (PM10) or (PM2.5), fluoride, heavy metals, SVOC, etc. in the ambient atmosphere. It can be used for routine and emergency monitoring of gaseous substances and aerosols by departments such as environmental protection, health, labor, safety supervision, military, scientific research, and education.

Product Details



1. Product Overview

Yun TangPortable AC/DC dual-purpose atmospheric samplerSampling is an instrument used to capture particulate matter (TSP, PM10, PM2.5, etc.) and various gas components (SO2, NOx, etc.) samples in the atmosphere. The development process of this sampler extensively solicited opinions from experts and users, and applied high-tech in current fields such as computers, sensors, and new materials. It has reliable quality, stable performance, and long service life.


2. Scope of application

Yun TangPortable AC/DC dual-purpose atmospheric samplerUsing solution absorption method to collect various harmful gases in the ambient atmosphere and indoor air; The filter membrane weighing method is used to capture total suspended particles (TSP) and inhalable particles (PM10) or (PM2.5), fluoride, heavy metals, SVOC, etc. in the ambient atmosphere. It can be used for routine and emergency monitoring of gaseous substances and aerosols by departments such as environmental protection, health, labor, safety supervision, military, scientific research, and education.


3. Adopt standards

  • HJ 618-2011 "Determination of PM10 and PM2.5 in ambient air by gravimetric method"

  • HJ 656-2013 Technical Specification for Manual Monitoring Method (Weight Method) of Environmental Air Particulate Matter (PM2.5)

  • HJ 93-2013 "Technical Requirements and Detection Methods for Particulate Matter (PM10 and PM2.5) Samplers in Environmental Air"

  • HJ/T 374-2007 Technical Requirements and Testing Methods for Total Suspended Particle Samplers

  • HJ/T 375-2007 "Technical Requirements and Testing Methods for Environmental Air Samplers"

  • HJ/T 376-2007 "Technical Requirements and Testing Methods for 24-hour Constant Temperature Automatic Continuous Environmental Air Samplers"

  • JJG 956-2013 Atmospheric Sampling

  • JJG 943-1998 "Total Suspended Particle Sampler"

  • HJ 955-2018 "Determination of Fluoride in Environmental Air - Membrane Sampling/Fluoride Ion Selective Electrode Method"

  • HJ 657-2013 "Determination of Lead and Other Metallic Elements in Air and Exhaust Particulate Matter by Inductively Coupled Plasma Mass Spectrometry"


4. Technical features

1) One machine for multiple uses, with two constant temperature and current atmospheric sampling channels and one TSP sampling channel, independent control and flexible configuration;

2) Adopting a high negative pressure imported fan with a load capacity greater than 20kPa at 100L/min;

3) Adopting a 7.0-inch wide temperature high brightness color touch display screen, it is clear and visible under sunlight, with a beautiful interface and easy operation;

4) Dual operation mode of buttons and touch, suitable for various user operating habits;

5) Massive data storage, with a storage capacity of over 100000 sets of data;

6) The sampling flow rate of particulate matter can be set, and when used in conjunction with corresponding sampling heads, it can be used for sampling fluoride, heavy metals, SVOS, etc;

7) Using imported sampling pumps, with high load capacity, low noise, stable flow rate, and long service life;

8) Automatic measurement of temperature and air pressure, automatic calculation of standard sampling volume;

9) Small size, light weight, easy to carry;

10) Automatic protection of interrupted power data during the sampling process, and resuming sampling after power is received;

11) Dual data output mode, capable of Bluetooth printing or USB export;

12) Aluminum alloy material sampling head, anti-static adsorption;

13) The whole machine adopts excellent dust-proof and waterproof design, which can ensure normal operation in rainy and snowy weather;

14) The whole machine is designed with electromagnetic compatibility in mind and has strong anti-interference and anti radiation capabilities.


5. Technical indicators


Main parameters parameter range resolution accuracy
H6 (high negative pressure type) Sampling flow rate of particulate matter (10~130)L/min 0.1L/min Better than ± 2.0%
H7 (high negative pressure+dual constant current) Sampling flow rate of particulate matter (10~130)L/min 0.01L/min Better than ± 2.0%
Route A, Route B (0.100~1.000)L/min 0.001L/min Better than ± 2.5%
traffic stability

Better than ± 2.0%
Traffic repeatability

Better than ± 2.0%
load capacity Overcoming -20kpa resistance at a flow rate of 100L/min
Pre measurement pressure (-35~35)kpa 0.01kpa Better than ± 2.5%
atmospheric pressure (50~110)kpa 0.001kpa Better than ± 500pa
sampling time 1min~99h59min 1min Better than ± 0.2%
Equidistant sampling time Set freely within 99 hours and 59 minutes
Equal interval sampling frequency 1 to 99 times
noise <60db(A)
Overall dimensions (WxDxH) mm 165x330x275
weight About 6.5kg
power supply AC220V±10% 50Hz
power consumption <100W
sampling head PM2.5 cutting characteristics Da50=(2.5±0.2)um & g=(1.2±0.1)um
PM10 cutting characteristics Da50=(10±0.5)um & g=(1.5±0.1)um
entry speed 0.3m/s
b/a 0.625
Effective filter membrane diameter φ80mm
connector M20x1.5