Photovoltaic module temperature and humidity cycling test roomTechnical specifications and parameters:
⑴model:GDJS-0248B
⑵Studio size:(D)1350x (W)800 x (H)2100(mm)
⑶Temperature range:-40℃~100℃
Alternating temperature range:
⑷ Humidity range:30%~98%R·H(40~90℃)(Controllable and Adjustable)
Alternating humidity:75%~95%R·H(25~
⑸Temperature fluctuation:≤±0.3℃
⑹Humidity fluctuation:±2.5%R·H
⑺Temperature uniformity:±1℃
⑻Humidity uniformity:+2/-3 %R·H
⑼Heating rate: Heating rate3-5℃/min
cooling rate0.7-
⑽Time range:0~9999Hadjustable
⑾Power Supply:ACØ3 380V 50HZ 30A
⑿Total power:8KW
SatisfyPhotovoltaic module temperature and humidity cycling test roomExperimental indicators:
⑴Cold and hot cycle test:
Photovoltaic modules operate at wind speeds not lower than2m·S-1In the experimental space, the temperature is-40℃±2℃and85℃±2℃Cycle between them. The maximum heating and cooling rate is not greater than3.5℃/ minThe constant temperature time at high and low temperatures throughout the entire process shall not be less than10minThe constant temperature time and cycle times can be freely set with different test standards.(The detailed cycle process is shown in the figure11)
⑵Wet---Cold (frozen) test:
Single room experiment method, placing photovoltaic modules in an environmental test chamber at room temperature, setting the required wet and hot conditions and low temperature conditions, as well as the number of cycles, in a programmable temperature and humidity controller, running the equipment, and monitoring the changes in the components during the experiment. The maximum and minimum temperatures should be within the set values±2℃Within and above room temperature, the relative humidity should be maintained at the set value±5%R·HWithin. Wet cold (frozen) test-40℃arrive85℃The number of cycles can be freely set.(85℃Cool to-40℃,Heating and cooling rate:Zui High200℃/h.)(The detailed cycle process is shown in the figure12)
(3)Double85Damp heat test:
Place the photovoltaic module in an environmental testing chamber at room temperature and set the standard humidity and heat conditions required by the programmable temperature and humidity controller(85℃,85%R·H)Set the required test time, and the temperature should be within the set value±2℃Within, the relative humidity should be maintained at the set value±5%R·Hwithin.Test time:3000h. (From room temperature to85℃perhaps85℃Reduce to room temperature,Heating and cooling rate:Zui High100℃/h)