- Phone
-
Address
Room 516, No. 1187 Aksu Road, Shanghai
Shanghai Chenqiao Biotechnology Co., Ltd
Room 516, No. 1187 Aksu Road, Shanghai
Introduction to PZ protein chromatography column:
Suitable for aqueous solution systems and solvent compatible with commonly used liquid chromatography applications, such as solvents for protein purification.
Low pressure or gravity self flowing economical modular columns can evenly distribute the eluent on the column bed.
The chromatography column can achieve axial compression technology (adjustable axial compression at one end and adjustable axial compression at both ends).
There are 9 diameters and various lengths.
Applicable places: protein purification system, high-pressure chromatography system, medium pressure preparative liquid chromatography system
Product feature: Basic zero dead volume
Working temperature: 4-40 ℃
PH value: 1-14
Introduction:
PZ protein chromatography columns are suitable for aqueous systems and are compatible with common liquid chromatography solvents, such as those used in protein purification.
These economical modular columns utilize low-pressure or gravity flow, ensuring uniform distribution of eluent across the column bed.
These columns are available with axial compression technology (one-end adjustable axial compression and two-end adjustable axial compression).
Available in 9 diameters and various lengths.
Applications: Protein purification systems, high-pressure chromatography systems, medium-pressure preparative liquid chromatography systems
Features: Virtually zero dead volume
Operating Temperature: 4-40°C
pH: 1-14
PZ protein layerChemical stability: Suitable for aqueous solutions and most solvents in liquid chromatography analysis applications. Not suitable for the following solvents: acetone, ketones, chlorinated hydrocarbons, fatty esters>10% NaOH,>10% HCl,>5% acetic acid or strong inorganic acids.
Technical specifications: borosilicate glass in glass column tube
Screen plate (column bed support) PP
Adjust the nut with formaldehyde plastic
Fixed Nut Acetal Plastic
Joint nut PP
Fixed nut PP
Chemical Stability:
Suitable for aqueous solutions and most solvents used in liquid chromatography applications. Not suitable for the following solvents: acetone, ketones, chlorinated hydrocarbons, aliphatic esters, >10% NaOH, >10% HCl, >5% acetic acid, or strong mineral acids.
Technical Specifications: Glass Column Tube: Borosilicate Glass
Frit (Column Bed Support): PP
Adjusting Nut: Acetal Plastic
Retaining Nut: Acetal Plastic
Connecting Nut: PP
Retaining Nut: PP
PZproteinColumn ordering information


Note: If using a column installer, select the corresponding connecting piece+fixed column length chromatography column of equal diameter
Remark: If you choose a column packer: just select the corresponding connector + a fixed column length chromatography column with equal diameter.