PVT thermoplastic material specific capacity tester temperature control: $r $n - operating temperature: room temperature+5 #176; ~400 #176; ℃ $r $n - Temperature controller: PID control $r $n - Temperature error: #177; 0.3 ℃ $r $n-Temperature controller resolution: 0.1 ℃
PVTThermoplastic material specific capacity testerFunction Description:
A.citation standards:ISO 17744
B.test method:Isothermal method
C.Overall Dimensions:1935x910x590mm
D.Total weight of the machine:about550kg
E.temperature control
-Operating temperature:room temperature+5°~400°℃
-thermostat:PIDcontrol
-temperature error:±0.3℃
-Temperature controller resolution:0.1℃
F.pressure control
-Load element specification:25KN
-荷重元精度:0.25%
-maximum pressure:2500bar
G.displacement measurement
-Maximum Test Journey:60mm
-Displacement measurement method:Optical ruler
-Optical ruler resolution:1um
H.Servo motor drive system
-Minimum displacement:0.12um
-Can set speed range:0~1000mm/min
I.Diameter of membrane cavity and plunger:p7.8mm
J.cooling method:High precision flow valve controls compressed air cooling
K.Operating interface:Touch screen
L.power supply:AC220V,3phase,60Hz