PVT-3 motor power frequency withstand voltage tester is suitable for whole machine power frequency withstand voltage test below 13.8KV or single wire rod (or formed coil) withstand voltage test
PVT-3 motor power frequency withstand voltage tester
according to the standard
- GB755-2008 "Rating and Performance of Rotating Electrical Machines"
- GB1032-2012 "Test Methods for Three phase Asynchronous Motors"
- GB1311-2008 "Test Methods for DC Motors"
- GB14711-2006 General Requirements for Safety of Small and Medium sized Rotating Electrical Machines
- GB 50150 "Standard for Hand over Test of Electrical Equipment in Electrical Equipment Installation Engineering"
- GB 50055-93 "Design Code for Distribution of General Electrical Equipment"
- DL/T846-2004 General Technical Conditions for High Voltage Testing Equipment
- GB4793-1984 "Safety Requirements for Electronic Measuring Instruments"
Main technical parameters
- Power supply voltage: 220V ± 5%; 50Hz/60 Hz ± 2%.
- Output voltage: 0-35kV; accuracy 2%
- Rated capacity: 50kVA;
- Breakdown discrimination current: 10mA-1500 mA can be set freely and continuously adjustable;
- Voltage endurance test set time range: 1s-99s
- Alarm: indicator light and sound and light alarm.
- Adopting high-voltage epoxy dry-type test transformer
- Using an electric voltage regulator
- Configure industrial specific micro printers for easy data storage
- Adopting grounding protection devices to ensure the safety of test personnel during operation
- Suitable for whole machine power frequency withstand voltage test below 13.8KV or single wire rod (or formed coil) withstand voltage test