Welcome Customer !

Membership

Help

Jilin Puretech Technology Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

PKL150 particle counter

NegotiableUpdate on 05/02
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The PKL150 particle counter instrument is developed based on the principle of optical resistance (shading method) and is used to detect the size and quantity of solid particles in liquids. It can be widely used in aviation, aerospace, aerospace, heavy machinery, power, petroleum, chemical, transportation, ports, metallurgy, machinery, automobile manufacturing and other fields, for hydraulic oil, lubricating oil, shale oil, transformer oil (insulation oil), turbine oil (turbine oil), teeth ..

Product Details

PKL150 Particle Counter
The instrument is developed based on the principle of light blocking method (light blocking method) and is used to detect the size and quantity of solid particles in liquids. It can be widely used in aviation, aerospace, aviation, heavy machinery, power, petroleum, chemical, transportation, ports, metallurgy, machinery, automobile manufacturing and other fields. It is used to detect solid particle pollution in hydraulic oil, lubricating oil, shale oil, transformer oil (insulation oil), turbine oil (turbine oil), gear oil, engine oil, aviation kerosene, water-based hydraulic oil and other oil liquids, as well as to sample and detect insoluble particles in organic liquids and polymer solutions.
Performance characteristics:
Adopting the principle of light blocking method, it has the advantages of fast detection speed, strong anti-interference ability, high accuracy, and good repeatability.
High precision sensors ensure high-resolution force and accuracy.
Precision syringe type sampling system achieves constant sampling speed and precise control of sampling volume.
Positive/negative pressure chamber device, realizing sample degassing and high viscosity sample detection.
Color LCD touch screen, touch operation, simple and convenient.
built-in NAS1638、ISO4406、GJB420B、GJB420A、AS4059F、GB/T14039、SAE749D、ROCT17216、DL/T432、ASTMD7619、IP564、SH/T0868 According to the particle pollution level standards, the required standards can be built in according to user requirements.
9900 particle sizes can be set for particle size analysis.
It can simultaneously store four calibration curves (latex ball calibration curve, ACFTD calibration curve, ISOMTD calibration curve, GOST calibration curve), and can be easily switched to reduce conversion errors.
The detection data storage function facilitates the archiving, retrieval, and analysis of detection data.
Built in printer that can directly print out inspection reports.
Built in Chinese input method to achieve Chinese annotation of detection reports.
The RS232 interface and powerful data software enable external computer operators or upper computers to control instruments and process detection data.
Equipped with magnetic stirring function to evenly distribute particles.
The pneumatic pump device is equipped with a gas filtration and purification system to avoid contamination of the sample.
Technical Indicators:
Light source: semiconductor laser
Particle size range: 0.8 μ m to 600 μ m (depending on the selected sensor)
Sensitivity: 0.8 μ m (ISO4402) or 3 μ m (c) (GB/T18854, ISO11171)
Detection channels: 16, adjustable particle size with an interval of 0.01 μ m
Sampling volume: 0.2-100ml, with an interval of 0.1ml
Relative error of sampling volume: better than ± 0.5%
Detection speed: 5-80mL/min
Cleaning speed: 5-80mL/min
Resolution: better than 10% (GBT18854-2002, ISO11171)
Overlap error limit: 12000~40000 particles/mL (depending on the selected sensor)
Particle count repeatability: RSD<>
Relative error of particle counting: ± 5%
Maximum vacuum in the pressure chamber: -0.08MPa
Maximum pressure of the pressure chamber: 1MPa
Test sample viscosity: ≤ 650cSt
Test sample temperature: 0 ℃~80 ℃
Working temperature: 0 ℃~60 ℃
Storage temperature: -30 ℃~80 ℃
Power supply: 100-245V, 49-62Hz
Dimensions: Host 430 × 320 × 590mm
Pneumatic pump 330 × 266 × 255mm
Net weight of the instrument: 30kg for the main unit and 10kg for the air pressure pump

PKL150 particle counter
The instrument is developed using the principle of photoresistance (shading method), used to detect the size and number of solid particles in liquids, and can be widely used in aviation, aerospace, aviation, heavy industry machinery, power, petroleum, chemical industry, transportation, port, metallurgy, In the fields of machinery and automobile manufacturing, the hydraulic oil, lubricating oil, rock shale oil, transformer oil (insulating oil), steam turbine oil (turbine oil), gear oil, engine oil, aviation kerosene, water-based hydraulic oil, etc. Solid particle pollution degree detection, and sampling and detection of organic liquid and polymer solution insoluble particles.
Performance characteristics:
Adopting the principle of photoresist method (shading method), it has the advantages of fast detection speed, strong anti-interference, high precision and good repeatability.
High-precision sensors ensure high-resolution force and accuracy.
Precision syringe sampling system to achieve constant sampling speed and precise control of sampling volume.
Positive / negative pressure pneumatic chamber device to achieve sample degassing and high viscosity sample detection.
Color LCD touch screen, touch operation, simple and convenient.
Built-in NAS1638, ISO4406, GJB420B, GJB420A, AS4059F, GB / T14039, SAE749D, ROCT17216, DL / T432, ASTMD7619, IP564, SH / T0868 and other particle pollution degree standards, and can be built according to user requirements.
9900 particle sizes can be set to facilitate particle size analysis.
Four calibration curves (latex ball calibration curve, ACFTD calibration curve, ISOMTD calibration curve, GOST calibration curve) can be stored at the same time, and can be easily switched to reduce the conversion error.
Test data storage function, convenient for archiving, retrieval and analysis of test data.
Built-in printer, can directly print out the test report.
Built-in Chinese input method to realize the Chinese labeling of the test report.
RS232 interface and powerful data software can realize the control of the instrument and the processing of the detection data by the external computer or the host computer.
With magnetic stirring function to make the particles evenly distributed.
The pneumatic pump device is equipped with a gas filtration and purification system to avoid contamination of the sample.
Technical index:
Light source: semiconductor laser
Particle size range: 0.8μm ~ 600μm (depending on the selected sensor)
Sensitivity: 0.8μm (ISO4402) or 3μm (c) (GB / T18854, ISO11171)
Detection channels: 16, the particle size can be arbitrarily set at intervals of 0.01μm
Sampling volume: 0.2 ~ 100ml, interval 0.1ml
Relative error of sampling volume: better than ± 0.5%
Detection speed: 5 ~ 80mL / min
Cleaning speed: 5 ~ 80mL / min
Recognition: better than 10% (GBT18854-2002, ISO11171)
Coincidence error limit: 12000 ~ 40,000 grains / mL (depending on the selected sensor)
Particle count repeatability: RSD <>
Relative error of particle counting: ± 5%
Maximum vacuum of air pressure cabin: -0.08MPa
Maximum pressure of air pressure cabin: 1MPa
Test sample viscosity: ≤650cSt
Test sample temperature: 0 ℃ ~ 80 ℃
Working temperature: 0 ℃ ~ 60 ℃
Storage temperature: -30 ℃ ~ 80 ℃
Power supply: 100 ~ 245V, 49 ~ 62Hz
Dimensions: main machine 430 × 320 × 590mm
Pneumatic pump 330 × 266 × 255mm
Net weight of the instrument: 30kg of host, 10kg of pneumatic pump