Welcome Customer !

Membership

Help

Jilin Puretech Technology Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

PCNQ601C Automatic Trace Cloud Point Tester

NegotiableUpdate on 05/02
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

This measuring instrument is a fully automatic device used for low-temperature performance testing according to the standard testing method ASTM D7683. PCNQ601C integrates numerous new technologies, with a compact body that has ultra fast cooling speed and a cooling depth of up to -90 ℃. It does not require any additional cooling source and uses a safe and environmentally friendly metal bath, eliminating the pollution caused by the evaporation of liquid refrigerant on the environment ..

Product Details


PCNQ601CType fully automaticMicro cloud point analyzer

This measuring instrument is a fully automatic device used for low-temperature performance testing according to the standard testing method ASTM D7683. PCNQ601C integrates numerous new technologies, with a compact body that has ultra fast cooling speed and a cooling depth of up to -90 ℃. It does not require any additional cooling source and uses a safe and environmentally friendly metal bath, which eliminates the pollution of liquid refrigerant volatilization on the environment. During the experimental process, it also avoids the safety hazards of traditional alcohol bath flammability. The detection process is automated, and the temperature of the cold trap is automatically adjusted during the testing process without the need for manual intervention. And it has precise judgment, precise heating control, and simple and convenient operation, all of which ensure that PCNQ601C can quickly, safely, and accurately obtain the cloud point of the sample.

feature
>Fully automatic micro cloud point analyzer that meets ASTM D7683 and other standards
>Accurate and sensitive cloud point automatic detection
>The fully automated testing process saves you time
>Only 2-3ml of test sample is needed
>The refrigeration system is safe and environmentally friendly, and the metal bath does not require liquid refrigerant
>Ultra fast cooling speed, the cold bath only takes 15 minutes from room temperature to -90 ℃
>Ultra low cooling depth, up to -90 ℃ cooling depth

Key function
Fully comply with the requirements of the standard
By using the PCNQ601C micro cloud point analyzer, you can accurately measure the temperature. The fully automatic micro cloud point analyzer fully complies with the requirements of ASTM D7683 standard method.
ASTM D7683 was officially adopted in 2011, and PCNQ601C uses this method to accurately obtain the cloud point of the sample. In testing, the detection cycle of PCNQ601C can be set to 1 ℃ or 0.1 ℃. In this way, the detection accuracy of the instrument has exceeded the national standard.
green and environmentally friendly
PCNQ601C, as a refrigeration instrument, adopts air cooling technology with low energy efficiency and low power consumption, which saves more energy consumption under the same cooling capacity. The cooling depth can reach up to -90 ℃, which enables certain previously impossible low-temperature tests to be completed.
Compared to the previous generation of instruments that used alcohol bath cooling, the metal bath eliminates the risk of alcohol being flammable and explosive during the testing process. Due to the improvement of refrigeration efficiency, the waiting time for startup has been greatly reduced, from 120 minutes waiting for the alcohol bath to cool down to 15 minutes.
No external cold source is required, and the integrated instrument reduces the volume of the separate structure by 40% compared to an external cold source.
Highly automated and efficient
PCNQ601C adopts modern design to provide you with excellent user experience. The instrument only needs to click the start button once from the beginning of the test to automatically complete all the testing processes. A graphical overview of the PCNQ601C measurement process, allowing you to keep track of the measurement progress at any time. In addition, operating this instrument allows you to review historical records and clearly view detailed measurement results. No need to use a separate computer, which can save valuable workspace in the laboratory.
Time is money! Automation is becoming increasingly important because it can reduce the workload of employees and improve efficiency within laboratories. In addition, the standardization of the system ensures reliable measurement results and avoids any risk of user errors.

Technical Specifications
Compliant with standard: ASTM D7683
Detection range: -100 ℃ to room temperature
Cooling depth: -90 ℃
Temperature measurement: sturdy metal material and Pt100 probe with built-in calibration program, equipped with calibration points
Detection interval temperature: Cloud point: 0.1 ℃~1 ℃
Cold bath medium: metal bath, without liquid refrigerant carrier
User interface: 7-inch color LCD display unit resolution: 1024 * 600
Host size and weight: W420 × D420 × H470 mm 26 kg
Power supply: AC 220V ± 5%


PCNQ601C Automatic Trace Cloud Point Tester

This tester is a fully automatic instrument for the determination of low-temperature performance according to the standard test method ASTM D7683. PCNQ601C integrates many new technologies. The compact body has an ultra-fast refrigeration speed, a minimum refrigeration depth of - 90 ℃, and no additional cold source is required. A safe and environmentally-friendly metal bath is used, which eliminates the environmental pollution caused by the volatilization of liquid refrigerant and avoids the flammable safety hazard of traditional alcohol bath during the experiment. The detection process is automatic and the cold trap temperature is automatically adjusted during the test without manual intervention. Moreover, it has accurate judgment, accurate heating control and simple and convenient operation, which ensures that PCNQ601C can quickly, safely and accurately obtain the cloud point of the sample.

Characteristic
>Fully automatic trace cloud point tester complying with ASTM D7683, etc
>Precise and sensitive automatic detection of cloud point
>Fully automated test process saves you time
>Only 2~3ml test sample is required
>The refrigeration system is safe and environmental-friendly, and the metal bath does not require liquid refrigerant
>Extremely fast refrigeration speed, only 15 minutes for cold bath from room temperature to - 90 ℃
>Ultra-low cooling depth, up to - 90 ℃

Key functions
Fully comply with the requirements of the standard
You can accurately measure the temperature by using the PCNQ601C Trace Cloud Point Tester. The fully automatic trace cloud point analyzer fully meets the requirements of ASTM D7683.
ASTM D7683 was formally adopted in 2011. PCNQ601C adopts this method to accurately obtain the cloud point of the sample. In the test, the detection period of PCNQ601C can be set to 1 ℃ or 0.1 ℃. In this way, the detection accuracy of the instrument has been higher than the national standard.
Green and environmental friendly
PCNQ601C, as a refrigeration instrument, adopts the air energy refrigeration technology with low energy efficiency and less power consumption, which can save more power consumption under the same cooling capacity. Refrigeration depths up to - 90 ° C allow some of the cold tests previously not possible to complete.
Compared with the previous generation of instrument using alcohol bath for cooling, metal bath eliminates the risk of flammable and explosive alcohol in the test process. As the refrigeration efficiency is improved, the waiting time for startup is greatly shortened, from 120 minutes to 15 minutes.
No external cold source is required, and the volume of the integrated instrument is reduced by 40% compared with the split structure of the external cold source.
Highly automated and efficient
PCNQ601Cs modern design gives you an excellent user experience. The instrument can automatically complete all test procedures by clicking the start button once from the start of test. A graphic overview of the PCNQ601C measurement process allows you to keep track of the measurement progress. In addition, operating this instrument allows you to look through historical records and clearly view detailed measurements. No additional computers are required, saving valuable bench space in the lab.
Time is money! Automation is becoming more and more important – because it can reduce the workload of employees and improve the efficiency in laboratories. In addition, standardization of the system ensures reliable measurements and avoids the risk of any user error.

Technical parameter
Comply with ASTM D7683
Detection range: - 100 ℃ to room temperature
Refrigeration depth: - 90 ℃
Temperature measurement: Rugged metal and Pt100 probe with built-in calibration procedure, complete with calibration points
Detection interval temperature: cloud point: 0.1 ℃ - 1 ℃
Cold bath medium: metal bath, without liquid secondary refrigerant
User interface: 7-inch color LCD unit resolution: 1024 * 600
Dimensions and weight of main machine: W420 × D420 × H470 mm 26 kg
Power supply: AC 220V ± 5%