Welcome Customer !

Membership

Help

Shanghai Nianci Machinery Equipment Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Shanghai Nianci Machinery Equipment Co., Ltd

  • E-mail

  • Phone

  • Address

    Building 1, Haida Industrial Park, No. 32 Wudong Road, Yangpu District, Shanghai

Contact Now

PARKER pressure sensor/Parker pump valve available for sale in stock

NegotiableUpdate on 05/19
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

PARKER pressure sensors/Parker pump valves for spot sale - Shanghai Nianci Machinery Equipment Co., Ltd. Parker's sensor products have been widely used in the hydraulic and pneumatic fields, becoming a competitive product line.

Product Details

PARKER pressure sensor/Parker pump valve available for sale in stock-Shanghai Nianci Machinery Equipment Co., Ltd, Parker's sensor products have been widely used in the hydraulic and pneumatic fields, becoming a competitive product line

The measurement and analysis of various hydraulic values are fundamental requirements in both the industrial and construction machinery industries. Some hydraulic values that undergo high-speed changes, such as valve opening and closing, cylinder stroke, peak pressure, differential pressure, and flow rate changes, must be measured and recorded in real time. By using Parker's diagnostic equipment, you can obtain key parameters in your system with just one click operation. In recent years, the application of hydraulic systems in the fields of transmission and control has been continuously increasing, and this trend is particularly significant in machinery, equipment, and automated manufacturing. Parker's diagnostic equipment, especially the launch of the Service Master Plus, can help you participate in these new trends, measure, display, and analyze hydraulic systems, and easily handle complex processes. Its applications mainly include preventive maintenance, debugging and operation, fault analysis, and equipment optimization. Parameters that need to be measured in hydraulic systems: pressure/peak pressure, temperature, liquid level, flow rate, and RPMSpeed up.

T7DS B42 1R00 A1MO 024-76522-0
HC20TV63/32K/1100/ZA0ZB0/XAM0/150
HC20TV100/50U/85/ZAOZBO/L180
528N-6
588N-8-DL
D3FPE50YB9HB7023P80
IPD12223130
PWDXXA-400-20
VA01PLC24-1P
MV600S
P3NRA18BPP
P2E-QV32C3
NU41233184/CD2HRKS34MC-M2211 oil cylinder seal
3349116318 PGP511A0080CL6H2NE5E3B1B1
3349116125 PGP511A0040CK1H2NE3E2B1B1
T6CC 006 003 1R02 C111
D41FBB32FC5NKW0
3721560 F12-030-MF-IV-K-000-0000-P0
LPSS6EBM10MPC1
944443Q
SD41FBB32FC5NKW0

workIndustrial automation is the major direction of future social development, and as a pioneer in the field of fluid transmission, Parker has also been committed to the research and development of electro-hydraulic integration. Parker's SenoControl products meet the technical standards of industrial measurement and control. We have also improved the sensors specifically for automation technology and walking hydraulic requirements, making them suitable for most product lines in industrial and engineering applications. Parker SenoControl products have a sturdy structure, diverse varieties, long-term stability, anti-interference and high-quality characteristics, and have extensive application experience. Its main applications include test benches, general machine tool equipment, material conveying equipment, walking hydraulic, pneumatic equipment, and hydraulic equipment.


1. Correct installation method for PARKER pressure sensor:

(1) Verify the frequency response value of the pressure sensor under normal atmospheric pressure and standard temperature conditions using appropriate instruments.

(2) Verify the correctness of the coding of the pressure sensor and the corresponding frequency response signal.

2. Determine the specific installation location

In order to determine the number and specific installation location of the PARKER pressure sensor, it is necessary to consider each inflation section of the inflation net.

(1) The pressure sensor must be installed along the cable, preferably at the cable joint.

(2) Each cable should be equipped with no less than 4 pressure sensors, and the two pressure sensors near the telephone office should be no more than 200m apart.

(3) Install one at the beginning and one at the end of each cable.

(4) Each cable should have one branch point installed. If two branch points are close together (less than 100m), only one can be installed.

(5) One cable should be installed at the location where the cable laying method (overhead, underground) changes

(6) For cables without branches, due to the consistent cable program of the base line, the installation spacing of pressure sensors should not be more than 500m, and the total number should not be less than 4.

(7) In order to facilitate the determination of the fault point of the pressure sensor, in addition to installing the pressure sensor at the starting point, an additional one needs to be installed at a distance of 150-200m from the starting point. Of course, in the design, economic and technical factors must be considered. If the pressure sensor does not need to be installed, it should not be installed. Welcome to inquire and place ordersPARKER pressure sensor/Parker pump valve available for sale in stock-Shanghai Nianci Machinery Equipment Co., Ltd