This device is mainly designed for AC withstand voltage testing of cross-linked cables, hydroelectric generators, main transformers, busbars, GIS, etc. It has a wide range of applications and is an ideal withstand voltage equipment for high-voltage testing departments and power installation and maintenance engineering units at the local, municipal, and county levels.
The device mainly consists of a variable frequency control power supply, an excitation transformer, a reactor, a capacitive voltage divider, and a compensation capacitor (optional).
Product Name: Series Resonance, Variable Frequency Resonance, Variable Frequency Series Resonance, Series Resonance Test Equipment, Series Resonance Voltage Endurance Device, Cable Voltage Endurance Series Resonance Device
| ambient temperature | -100oC-50oC |
| relative humidity | ≤90%RH |
| altitude | ≤1000m |
| Rated capacity | 324kVA |
| input power | Three phase 380V voltage, frequency 50Hz |
| rated voltage | 54kV |
| rated current | 6A |
| operating frequency | 30-300Hz |
| Device output waveform | sine wave |
| waveform distortion rate | Output voltage waveform distortion rate ≤ 1% |
| working hours | Under rated load, continuous operation for 60 minutes is allowed; Overvoltage 1.1 times for 1 minute |
| temperature rise | Temperature rise ≤ 65K after 60 minutes of continuous operation under rated load |
| Quality factors | The device itself has a Q ≥ 30 (f=45Hz) |
| protection function | Provide overcurrent, overvoltage, and flashover protection for the test sample (see the variable frequency power supply section for details) |
| measurement accuracy | Effective value of the system at level 1.5 |
| Rated capacity | 9kVA |
| input voltage | 0-400V, single-phase |
| output voltage | 3kV |
| structure | dry-type |
| weight | About 50kg |
| Rated output capacity | 18kW |
| working power supply | 380 ± 10% V (three-phase), power frequency |
| output voltage | 0-400V, single-phase |
| Rated input current | 45A |
| Rated output current | 45A |
| Voltage resolution | 0.01kV |
| Voltage measurement accuracy | 1.5% |
| Frequency adjustment range | 30-300Hz |
| Frequency adjustment resolution | ≤0.1Hz |
| frequency stability | 0.1% |
| runtime | Continuous 60 minutes at rated capacity |
| noise level | ≤50dB |
| Rated capacity | 54kVA |
| rated voltage | 27kV |
| rated current | 2A |
| Inductance | 68H/single section |
| Quality factors | Q≥30(f=45Hz) |
| structure | dry-type |
| weight | About 75kg |
| rated voltage | 60kV |
| High voltage electrical capacity | 2500pF |
| dielectric loss | tgσ≤0.5% |
| Voltage divider ratio | 1000:1 |
| measurement accuracy | Effective value level 1.5 |
| weight | About 10kg |
1. The appearance of the product is subject to the actual product. Technical parameters and models are subject to change without prior notice. If there is any act of theft or copying, legal responsibility will be pursued.
2. To learn more about Huatian products, please enter the product center. Service Hotline: 400-8855-448
Power frequency series resonant boost device (CVT)
Product features
Product Characteristics
1. The device has protection functions such as overvoltage, overcurrent, zero start, and system detuning (flashover). The overvoltage and overcurrent protection values can be set according to user needs, and the flashover protection will be activated when the test sample flashover to protect the product.
2. The entire device is lightweight and easy to use on site.
3. The device has three working modes, which are convenient for users to flexibly choose according to the on-site situation and improve the testing speed. The working modes are: fully automatic mode, manual mode, and automatic tuning manual boost mode.
6. Adopting DSP platform technology, it is convenient to add or remove functions and upgrade according to user needs, making the human-machine exchange interface more user-friendly.












Huatian Electric Power has a self owned factory area of 4500 square meters and a total of more than 100 employees. The series resonant device is widely used in industries such as power, metallurgy, petroleum, and chemical engineering. It is suitable for the handover and preventive testing of large capacity, high-voltage capacitive samples such as power cables, power transformers, hydroelectric generators, GIS, etc.
Engineering Case
In early September, Huatian Power received an invitation for after-sales service from a customer. Our after-sales engineer, Mr. Zhang, immediately went to the customer's location to provide technical support for the HTXZ series resonant withstand voltage device and other equipment purchased from our company.
In early September, at the invitation of the customer, Mr. Wang, an after-sales engineer from Huatian Electric Power, went to Heze City, Shandong Province to provide technical support for the HTXZ-2000kVA/500kV large series resonant withstand voltage test device purchased by the customer from our company.
Our company has arranged after-sales colleagues to provide after-sales service for Wenzhou Longwan Power Supply Company, training equipment: HTXZ-405kVA/108kV variable frequency series resonant AC withstand voltage test device.
In November, our company received an after-sales invitation from Heilongjiang Jingrui Construction Engineering Co., Ltd. and immediately arranged for after-sales personnel to go to Lijiang City, Yunnan Province, where the customer is located, to provide training on the HTXZ cable AC withstand voltage series resonant device they purchased.
In early November, upon receiving a training invitation from Wistron Automatic Equipment Wuxi Co., Ltd., our after-sales colleagues immediately went to Huai'an City to provide training on the instruments purchased by customers.
After sales service of China Railway Construction Heavy Industry Group Co., Ltd




answer questions and resolve doubtsDispel Doubts
Huatian Electric Power is a high-tech company established in 2004 through the restructuring of the original Wuhan High Voltage Research Institute Third Industry. Its predecessor, Wuhan High Voltage Research Institute High Test Equipment Manufacturing Factory, was founded in 1992 and was one of the early manufacturers in China engaged in high voltage testing. With years of experience in the research and development of series resonance technology, we have sold over a thousand sets of series resonance devices.Q
During long-term testing, the high voltage of resonance will gradually increase slowly, but the low voltage remains unchanged?A
After reaching the test voltage, both the low and high voltage of resonance will stop boosting and remain at the current voltage. However, due to the fact that the tested objects of resonance are mostly those with large capacitance, there will be a capacitance rise phenomenon during withstand voltage, especially for a long time. Therefore, the high voltage will gradually and slowly rise.Q
Resonance occurs during the voltage boosting process. When the voltage reaches a certain level, the high voltage no longer rises, but the low voltage continues to rise normally. The voltage waveform on the instrument interface fluctuates up and down?A
Resonant boost indicates that there is no problem with the matching between the resonance and the test sample, and the voltage has not continued to rise, indicating that the test voltage has not been reached. Therefore, there is no overvoltage protection, and the low voltage is boosting normally. The output power of the resonance is also normal. If there is no occurrence of disharmony or breakdown, it indicates that the ground insulation of the test sample is normal. After ruling out the above faults, combined with the waveform of voltage fluctuations, it indicates that discharge occurred during the test, which may exist in the resonant equipment or the test sample.Q
Resonant high voltage cannot be raised to the test voltage, but the theories of reactors and excitation transformers can be satisfied?A
The high voltage of resonance is indeed related to the selection of output voltage for the combined excitation of the reactor, but it is also related to the power factor and quality factor Q of the entire resonant circuit composed of the reactor and the test object. If the quality factor Q of the entire system is low, then most of the system is reactive power, and the active power is too small, so the high voltage cannot be raised very high. And the quality factor Q is related to the frequency f of resonance, so in the above situation, we need to further adjust the reactor combination to change the frequency.Q
Product Atlas
Product Picture
Product Attachment Diagram
complete set
Incentive Transformer
Variable Frequency Power Supply
reactor
Compensation capacitor
voltage divider
Voltage divider signal line
power cord
Reactor series parallel line
Reactor series parallel line
Variable frequency source output line
High voltage output line
Incentive variable output line
ground wire
Specialized testing line crocodile clip
Specialized testing line pliers
USB drive
Instruction manual, inspection certificate, certificate of conformity
Product detail images
Incentive Transformer
Incentive Transformer Panel
Excitation transformer input
Excitation transformer terminal
Variable Frequency Power Supply
Variable frequency power supply display screen
Variable frequency power input
Variable frequency power supply grounding
Variable frequency power printer
Variable frequency power switch
Voltage divider base
Production process diagram
On site production drawing
On site production drawing