Outline drawing of safety relay PILZ Pilz 774303
Input: 1/2 channel wiring with/without contact short circuit detection function, output: 2 N/O, monitored for startup, UB=24 V AC/DC, Width: 22.5 mm, integrated screw terminal, monitoring emergency stop device and safety door.
A safety relay is composed of several relays and circuits, designed to complement each other's abnormal defects and achieve the complete function of a correct and low misoperation relay. The lower the error and failure values, the higher the safety factor. Therefore, multiple safety relays need to be designed to protect machinery of different levels, with the main goal of protecting machinery operators exposed to different levels of danger.
Climate suitability standards for equipment usabilityEN 60068-2-78
Environmental temperature expressed in degrees Celsius-10 °C
A safety relay is a necessary control component in a safety circuit, which receives safety inputs and outputs deterministic switch signals to the control circuit of the equipment through internal circuit judgment. Simply put, safety relays are of the dual channel signal type, and can only function properly when both channel signals are normal; During the working process, as long as any channel signal is disconnected, the safety relay will stop outputting until both channel signals are normal and reset before it can work normally.
Humidity rating93 % r.h.40 °C
Allow/Do not allow condensationNot allowed
Do you need a compact safety unit with an emergency stop button or safety door monitoring function? Monitor two security functions simultaneously using a single unit. Reduce wiring. The width is only 22.5 mm, which reduces the requirement for space inside the control cabinet to its limit. Implement functionality through internal logical AND operation. Each safety function has a separate signal output:
PNOZ e5.11p simultaneously monitors the combination of emergency stop button/safety door or two safety doors.
PNOZ e5.13p can also be connected to PSENmag safety switch.
Continuous line checks conducted by PLIDys have identified all potential wiring errors, eliminating the need for customized testing
PLIDys can be connected to existing lines, reducing additional costs
Small size, easy to integrate into existing devices
Access directly through the QR code on the unit to improve service speed. Assemble quickly with spring clips: no tools required
Outline drawing of safety relay PILZ Pilz 774303