Orion Conductivity Meter Set

NegotiableUpdate on 05/20
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The Orion Conductivity Meter Set PSTAR2120 is available in 6 languages including Chinese and English, and is displayed on a large LCD screen to show conductivity TDS、 The laboratory desktop conductivity meter has AUTO-READTM function for salinity, resistivity, temperature, as well as time, date, sample number, user number, and calibration point icons. When the data is stable, the reading can be locked and the indicator icon will be displayed.

Product Details

Orion Conductivity Meter SetPSTAR2120 aims to provide accurate and reliable conductivity, TD, Salinity, resistivity, and temperature analysis,

Very suitable for laboratories that want modern instruments with advanced performance. The Orion Pro STAR instrument panel has a high score of 7 inches

Resolution color display screen with responsive capacitive touch screen, dedicated to ensuring ease of use and can be used for your testing needs

New instrument. The Orion Pro STAR instrument provides on-screen guidance and step-by-step instructions, and supports GLP compliance

Calibration logs and data logs stamped with date and time.

The Orion Pro STAR EC212 conductivity meter is designed to provide accurate and user-friendly instruments in laboratories that require modern and easy-to-use instruments

Reliable testing, performance, and reliable data reporting.

Orion Conductivity Meter SetPSTAR2120 Product Introduction:

Using the Instrument Setup Wizard makes instrument startup easy, as it guides users through important instrument and measurement settings. Use the screen instrument tour and guide for calibration,

Measure, instrument connections, and electrode support components to better understand instrument operation, warnings, and required maintenance. Use guided calibration with step-by-step instructions to perform calibration correctly and ensure

Accurate, reliable, and reportable measurement values.

Easily view large 7-inch measurements. Color graphic touch screen display. Select basic, advanced, or custom measurement display formats to view only the information you like in measurement mode.

Select the chart view to display measurement values in the chart for studying measurement and time.

When conducting measurements, use optional instrument accessories (including USB barcode scanner, USB keyboard or USB mouse) to easily input sample identification information into the instrument. Use optional options

The instrument controlled and meter driven stirrer probe easily and evenly stirs the sample, eliminating the need for magnetic stirring plates and bars.

Use date and timestamp to save, display and export up to 20 calibrations per parameter. Filter calibration logs through users and export calibration logs by date range or all.

It is easy to save measurement values to data logs for long-term data retention. Use date and time stamps to save, display, and export up to 10000 data log sets. check

Look at a single data log set that contains a large amount of measurement information, which is listed in an easy to read screen list format. By user, date and time or log number, and by date and

Time range, log number range, or filtered data log of all exported data logs.

Output instrument data logs, calibration logs, and methods to printers, computers, or USB flash drives. Save data to a computer or USB drive as comma separated values (CSV)

Files can be imported into programs such as Microsoft Excel, or data can be saved to a USB drive as a report file for printable recording. Customize exported files to

Including all data, advanced, intermediate or basic data, only obtaining the information required for record keeping. Use remote commands to interface instruments with computer programs, including LIMS, through bidirectional communication,

Hyper Terminal, Putty, and other data collection software.

Save measurement settings for standardized analysis and SOP using instrument methods. Each parameter can store up to 10 methods. Import and export methods from other Orion Pro Star series instruments,

To standardize your testing.

Activate security mode and assign up to 3 administrators, with up to 30 users having separate account login and password protection. Administrators can choose from pre-defined user access levels

Instrument functions. Control access date and time settings, instrument settings, data logs and calibration logs, or customize access levels for each user, from accessing basic data sets. pipe

Administrators can also export user lists and audit trails to help ensure the integrity of digital data.

Operate the accompanying electrode bracket to facilitate safe and smooth movement of electrodes into and into the solution. The weighted base of the electrode bracket provides flexible placement for the brackets around the instrument. make

Use various electrode holder options to secure various electrodes. Organize the electrode cables neatly in the built-in side channels of the bracket.

Product Features:

Large 7-inch, high-resolution color display

Responsive touch screen, gloveable

Angle display to help ensure ergonomic viewing

Streamlined, easy-to-use user interface

Vertical instrument orientation helps optimize the reference space

Support GLP compliance

Store 20 calibration logs for each parameter using date and time

Store 10000 data log sets with dates and times

Output to printer, computer, or USB flash drive for long-term data retention

Enter an example ID with optional USB barcode scanner, USB keyboard, or USB mouse

Technical parameters for stirring samples using instrument control and instrument driven stirrer probes:

Accuracy (conductivity): ± 0.5% reading

Output: USB flash drive, computer or printer (Stara-106)

Includes: Instrument with electrode holder, USB flash drive, computer cable, 100-240V 50/60Hz universal power adapter (electrodes purchased separately)

Suitable for (application): Instruments with brackets, purchase application electrodes separately

Measurement modes: conductivity, temperature, temperature, salinity, temperature, resistivity, resistivity at temperature

Battery constants: 0.100 cm-1, 0.475 cm-1, 0.550 cm-1, 1.000 cm-1, 10.00 cm-1 or user-defined from 0.001 to 199.9 cm-1

Calibration: Conductivity, TD, Salinity, temperature

Calibration point (conductivity): 1 to 5 points

Calibration points: 1 to 5 (conductivity), 1 to 5 (TDS), 1 (salinity), 1 to 2 (temperature)

Range (conductivity): 0.010 μ s/cm to 3000 ms/cm

Resolution (conductivity): minimum 0.001 μ s/cm, automatic range, maximum 4 digits

Temperature compensation: Linear (0.00 to 10.00%/° C), NLFN (Nonlinear Natural Water), NLFU (Nonlinear Ultra Pure Water), EP/USP or OFF

Reference temperature (metric): 5, 10, 15, 20, 25 or 30 ° C

Range (salinity): 0.010 to 80.00 ppt; 0.01 to 42.00 psu; Or 0.01 to 400.0% NaCl

Resolution (salinity): 0.001 ppt minimum value; 0.01 psu ; Or 0.01% NaCl, automatic range

Accuracy (salinity): ± 0.5% reading

Salinity measurement mode: natural seawater (PPT), practical salinity unit (PSU) or% NACL

Range (TDS): 0.010 ppm to 500.0 ppt (TDS coefficient of 1.00); Or 0.010 mg/l to 500.0 g/l (TDS coefficient of 1.00)

Resolution (TDS): 0.001 ppm or mg/l automatic range, up to 4 digits

Accuracy (TDS): ± 0.5% of readings

TDS factor range: linear (0.01 to 10.00), ISO/EN 27888,442,NACL

Temperature range (metric): -30 ° C to+130 ° C

Temperature range (imperial): -22 ° F to+266 ° F

Resolution (temperature): 0.1 ° C, 0.1 ° F

Accuracy (temperature): ± 0.3 ° C, ± 0.5 ° F

Range (resistivity): 1.0 Ω to 100.0M Ω

Temperature selection: Automatic use of ATC temperature sensor, ambient or manual

Temperature electrode calibration: 1 or 2-point temperature offset calibration

Display type: 7 inches. High resolution color graphic LCD

Backlight option: Yes

Storage: Non volatile

Data point: 10000 date and time stamps

Log function type: Automatic with automatic reading and timed reading modes, manual using continuous reading mode

Alarm output: Calibration reminder alarm, high and low limit alarm for each parameter

Input: CE, TUV 3-1, FCC Class A

Certification/Compliance: CE, TUV 3-1, FCC Class A

IP protection level: IP54

AC power adapter: 100-240 V 50/60 Hz power supply with wall plug, for export to Japan, Europe, UK/Singapore, Australia/New Zealand, and China

Dimensions (length x width x height): 218.9 x 153.2 x 91.33 millimeters; 8.62 x 6.03 x 3.60 inches.

Weight (metric): 1 kilogram

Weight (Imperial): 2.20 pounds

Model: EC212

Resolution (resistivity): minimum 0.1 Ω

Method: 10 Keyboard: Capacitive Touch Screen User Interface

Languages: Chinese, English, French, German, Italian, Japanese, Korean, Portuguese, Spanish

通道:1

Type: Conductivity reference meter

Accuracy (resistivity): ± 0.5% reading