Orion Conductivity Meter SetPSTAR2120 aims to provide accurate and reliable conductivity, TD, Salinity, resistivity, and temperature analysis,
Very suitable for laboratories that want modern instruments with advanced performance. The Orion Pro STAR instrument panel has a high score of 7 inches
Resolution color display screen with responsive capacitive touch screen, dedicated to ensuring ease of use and can be used for your testing needs
New instrument. The Orion Pro STAR instrument provides on-screen guidance and step-by-step instructions, and supports GLP compliance
Calibration logs and data logs stamped with date and time.
The Orion Pro STAR EC212 conductivity meter is designed to provide accurate and user-friendly instruments in laboratories that require modern and easy-to-use instruments
Reliable testing, performance, and reliable data reporting.
Orion Conductivity Meter SetPSTAR2120 Product Introduction:
Using the Instrument Setup Wizard makes instrument startup easy, as it guides users through important instrument and measurement settings. Use the screen instrument tour and guide for calibration,
Measure, instrument connections, and electrode support components to better understand instrument operation, warnings, and required maintenance. Use guided calibration with step-by-step instructions to perform calibration correctly and ensure
Accurate, reliable, and reportable measurement values.
Easily view large 7-inch measurements. Color graphic touch screen display. Select basic, advanced, or custom measurement display formats to view only the information you like in measurement mode.
Select the chart view to display measurement values in the chart for studying measurement and time.
When conducting measurements, use optional instrument accessories (including USB barcode scanner, USB keyboard or USB mouse) to easily input sample identification information into the instrument. Use optional options
The instrument controlled and meter driven stirrer probe easily and evenly stirs the sample, eliminating the need for magnetic stirring plates and bars.
Use date and timestamp to save, display and export up to 20 calibrations per parameter. Filter calibration logs through users and export calibration logs by date range or all.
It is easy to save measurement values to data logs for long-term data retention. Use date and time stamps to save, display, and export up to 10000 data log sets. check
Look at a single data log set that contains a large amount of measurement information, which is listed in an easy to read screen list format. By user, date and time or log number, and by date and
Time range, log number range, or filtered data log of all exported data logs.
Output instrument data logs, calibration logs, and methods to printers, computers, or USB flash drives. Save data to a computer or USB drive as comma separated values (CSV)
Files can be imported into programs such as Microsoft Excel, or data can be saved to a USB drive as a report file for printable recording. Customize exported files to
Including all data, advanced, intermediate or basic data, only obtaining the information required for record keeping. Use remote commands to interface instruments with computer programs, including LIMS, through bidirectional communication,
Hyper Terminal, Putty, and other data collection software.
Save measurement settings for standardized analysis and SOP using instrument methods. Each parameter can store up to 10 methods. Import and export methods from other Orion Pro Star series instruments,
To standardize your testing.
Activate security mode and assign up to 3 administrators, with up to 30 users having separate account login and password protection. Administrators can choose from pre-defined user access levels
Instrument functions. Control access date and time settings, instrument settings, data logs and calibration logs, or customize access levels for each user, from accessing basic data sets. pipe
Administrators can also export user lists and audit trails to help ensure the integrity of digital data.
Operate the accompanying electrode bracket to facilitate safe and smooth movement of electrodes into and into the solution. The weighted base of the electrode bracket provides flexible placement for the brackets around the instrument. make
Use various electrode holder options to secure various electrodes. Organize the electrode cables neatly in the built-in side channels of the bracket.
Product Features:
Large 7-inch, high-resolution color display
Responsive touch screen, gloveable
Angle display to help ensure ergonomic viewing
Streamlined, easy-to-use user interface
Vertical instrument orientation helps optimize the reference space
Support GLP compliance
Store 20 calibration logs for each parameter using date and time
Store 10000 data log sets with dates and times
Output to printer, computer, or USB flash drive for long-term data retention
Enter an example ID with optional USB barcode scanner, USB keyboard, or USB mouse
Technical parameters for stirring samples using instrument control and instrument driven stirrer probes:
Accuracy (conductivity): ± 0.5% reading
Output: USB flash drive, computer or printer (Stara-106)
Includes: Instrument with electrode holder, USB flash drive, computer cable, 100-240V 50/60Hz universal power adapter (electrodes purchased separately)
Suitable for (application): Instruments with brackets, purchase application electrodes separately
Measurement modes: conductivity, temperature, temperature, salinity, temperature, resistivity, resistivity at temperature
Battery constants: 0.100 cm-1, 0.475 cm-1, 0.550 cm-1, 1.000 cm-1, 10.00 cm-1 or user-defined from 0.001 to 199.9 cm-1
Calibration: Conductivity, TD, Salinity, temperature
Calibration point (conductivity): 1 to 5 points
Calibration points: 1 to 5 (conductivity), 1 to 5 (TDS), 1 (salinity), 1 to 2 (temperature)
Range (conductivity): 0.010 μ s/cm to 3000 ms/cm
Resolution (conductivity): minimum 0.001 μ s/cm, automatic range, maximum 4 digits
Temperature compensation: Linear (0.00 to 10.00%/° C), NLFN (Nonlinear Natural Water), NLFU (Nonlinear Ultra Pure Water), EP/USP or OFF
Reference temperature (metric): 5, 10, 15, 20, 25 or 30 ° C
Range (salinity): 0.010 to 80.00 ppt; 0.01 to 42.00 psu; Or 0.01 to 400.0% NaCl
Resolution (salinity): 0.001 ppt minimum value; 0.01 psu ; Or 0.01% NaCl, automatic range
Accuracy (salinity): ± 0.5% reading
Salinity measurement mode: natural seawater (PPT), practical salinity unit (PSU) or% NACL
Range (TDS): 0.010 ppm to 500.0 ppt (TDS coefficient of 1.00); Or 0.010 mg/l to 500.0 g/l (TDS coefficient of 1.00)
Resolution (TDS): 0.001 ppm or mg/l automatic range, up to 4 digits
Accuracy (TDS): ± 0.5% of readings
TDS factor range: linear (0.01 to 10.00), ISO/EN 27888,442,NACL
Temperature range (metric): -30 ° C to+130 ° C
Temperature range (imperial): -22 ° F to+266 ° F
Resolution (temperature): 0.1 ° C, 0.1 ° F
Accuracy (temperature): ± 0.3 ° C, ± 0.5 ° F
Range (resistivity): 1.0 Ω to 100.0M Ω
Temperature selection: Automatic use of ATC temperature sensor, ambient or manual
Temperature electrode calibration: 1 or 2-point temperature offset calibration
Display type: 7 inches. High resolution color graphic LCD
Backlight option: Yes
Storage: Non volatile
Data point: 10000 date and time stamps
Log function type: Automatic with automatic reading and timed reading modes, manual using continuous reading mode
Alarm output: Calibration reminder alarm, high and low limit alarm for each parameter
Input: CE, TUV 3-1, FCC Class A
Certification/Compliance: CE, TUV 3-1, FCC Class A
IP protection level: IP54
AC power adapter: 100-240 V 50/60 Hz power supply with wall plug, for export to Japan, Europe, UK/Singapore, Australia/New Zealand, and China
Dimensions (length x width x height): 218.9 x 153.2 x 91.33 millimeters; 8.62 x 6.03 x 3.60 inches.
Weight (metric): 1 kilogram
Weight (Imperial): 2.20 pounds
Model: EC212
Resolution (resistivity): minimum 0.1 Ω
Method: 10 Keyboard: Capacitive Touch Screen User Interface
Languages: Chinese, English, French, German, Italian, Japanese, Korean, Portuguese, Spanish
通道:1
Type: Conductivity reference meter
Accuracy (resistivity): ± 0.5% reading