- Phone
-
Address
Room 1229, Xinxin International West, No. 2 Jiayuan Road, Xiangcheng Economic Development Zone, Suzhou City
Suzhou Jiaye Instrument Co., Ltd
Room 1229, Xinxin International West, No. 2 Jiayuan Road, Xiangcheng Economic Development Zone, Suzhou City
NIPPON Denshoku ND12 Instrument Features:
l Compact and lightweight structure
Compact structure, light weight, easy to measure indoors and outdoors on site, and can be completed with one hand.
l Easy to operate
Turn on the power, stabilize and calibrate, then place the instrument in the correct positionPress the top of the instrument to test.
l precise positioning
The use of target positioning targets for precise positioning can achieve the function of measuring small area samples.
l Power saving design
built-in 4 Nickel chromium battery, if accidentally forgotten to turn off, the automatic shutdown function is provided 4 Planting self in different time periods Dynamic shutdown time to prevent battery waste.
lThis instrument has added the functions of measuring reflected light density and yellow density, and can also measureMultiple reflectivity measurements Reflected light density is used to measure silver luster, while yellow density is used to measure gold luster.
lData storage and batch output
Maximum data storage capacity 500 You can set the output range for the entire batch of data by yourselfBy connecting an external computer or printer Implement data output.
lAverage calculation function
Maximum computable 9 The average value of the secondary data, if there is an external device, can be output for each measurement and the average value.
lData compensation function
This function is very convenient, as it compensates for the calibration curve through data compensation, ensuring that the test results are consistent with previous model measurements Compatibility.
l Rich configuration
Serial printer;
Connect the data cable;
Computer software can collect, store, convert, and analyze data.
NIppon Denshoku ND12 技 technique ginseng number
measurement project |
Reflected light density, reflectivity, brightness,Y(yellow tones) ,B(White series) |
measurement range |
0.00 ~ 100% |
measure area |
Φ3.0mm ,Φ1.7mm ,Φ1.0mm |
lighting/Acceptance Condition |
Vertical lighting:0º~ 45ºCircular edge light receiving |
accuracy(reproducibility) |
Φ3.0mm(standard);±0.01D(2.0DOr lower) Φ1.7mm ;(Stop supply) Φ1.0mm ;±0.03D(1.0DOr lower);±0.10D(2.0DOr lower) |
Data compensation function |
The data compensation function ensures compatibility with previous model measurement results |
Average measurement |
One click operation calculation 2 ~ 9The average reflection intensity of a point |
Measurement data storage |
Maximum storage capacity 500 A data |
Overall dimensions |
length 210mm, Depth 72mm, height 50mm |
heavy quantity |
530 gram(including the battery) |
electricity source |
built-in Ni-Cd Battery,4.8V ,800mAh |
merit rate |
halogen lamp(about 2.856°K) |
select choose document |
Serial port printer(PR-95)Connect the cable and insert the data receiver Excel Spreadsheets, Accuracy Management Standard Board |
Note: The accuracy of the NIppon Denshoku ND12 model comes from the Japan Color Research Institute(JCRI)National standards