FESKS FSON 5350 controller can be paired with various online ion selective electrodes with different parameters, including KSIO 560/570 and KSIA 580/electrode, which can respectively measure fluoride ions, chloride ions, and calcium ions. The instrument is used for monitoring various types of water quality ions.
▶Ionic selective electrode, high cost-effectiveness and low investment
▶ Low power consumption of sensors and anti-interference design of internal circuits
▶ Imported chip components to ensure stable instrument measurement
▶ Chinese/English/Traditional Chinese language, easy to operate
▶ LCD displays measurement values, temperature, fault codes, current, and relay status
▶ 2-channel 4-20 mA current output, corresponding values can be set arbitrarily
▶ 2 sets of programmable independent relays set Hi/Lo alarm points
▶ A multifunctional relay with cleaning, cycle alarm, and error alarm functions
▶ Supports RS485 Modbus RTU standard protocol
▶ Historical curve, measurement data storage and record query function (500000 records)
Widely used for online ion concentration monitoring in water plants, power plants, semiconductors, steel, electroplating, environmental monitoring, discharge outlets, etc.
model |
FSON 5350 -ION |
function |
ION |
measurement range |
0.00-20.00/0.0-200.0/0.0-2000.0/0-20000 ppm |
Measurement resolution |
0.01/0.1/1ppm |
Measurement accuracy |
±0.01/±0.1/±1ppm |
Voltage input range |
0.0-1000.0mV |
Temperature compensation method |
Pt 1000/NTC 10K |
Temperature measurement range |
-10.0 -+130.0 ℃ |
Temperature compensation range |
-10.0 -+130.0 ℃(Manual)/Automatic) |
temperature resolution |
0.1 ℃ |
Temperature accuracy |
±0.2℃ |
input impedance |
>10¹² Ω |
Working environment temperature |
0 -+70℃ |
Storage environment temperature |
-20 -+70℃ |
display |
Backlit dot matrixLCD |
current output |
isolated 4 -20mA output, maximum load 500 Ω |
Accuracy of current output |
±0.05 mA |
RS485 |
Modbus RTU Standard Protocol |
communication rate |
9600 fixed |
Relay contact capacity |
2 sets of ON/OFF contacts, independently set Hi/Lo alarm points,5A/250VAC、5A/30VDC |
Language Selection |
English/Simplified Chinese |
Protection level |
IP65 |
power supply |
90 ~260VAC, Power consumption<5W,24VDC optional |
Protection level |
IP65 |
instrument/Hole size |
108mm*108mm*148mm/92*92mm |
Installation method |
Panel installation/Wall mounted installation/pipeline installation |
weight |
0.87Kg |
model |
Order Number |
description |
FSON 5350 |
50-5350-00 |
Ion concentration controller |
KSIO 560 |
22-0560-00 |
Fluoride ion electrode |
KSIO 570 |
22-0570-00 |
Chloride ion electrode |
KSIO 580 |
22-0580-00 |
Calcium ion electrode |