- Phone
-
Address
No. 1195 Pingliang Road, Shanghai
Shanghai Precision Instrument Co., Ltd
No. 1195 Pingliang Road, Shanghai
|
Sievers 400ESOnline total organic carbon(TOC)The analyzer provides online accessTOCAnalysis, in line withUSP<643>andEP characteristic 1.Preventing positive errors: Old styleTOCOnline analyzers may produce positive errors due to the oxidation of the sample by strong acids, resulting in the formation of organic carbon.SieversThe patented online monitoring technology is not easily affected by positive and negative errors. 2.21CFRPart11Features: For users who need to comply with electronic signature regulations, optionalDataGuardTMIt is pre installed on the computer and allows users to combine it with an electronic signature.DataGuardThe features include different levels of control interfaces accessed by each user, as well as traceability. 3.Simple system stability testing: patentedISOThe standard conveying system and user-friendly operating software make system stability testing simple, fast, and effective.400ESEnable operators to obtain compliance through a first level calibration program and automatic calibration systemUSP、EPThe desired outcome. 4.Measurable water containing ozone:400ESOzone containing water for pharmaceutical industry testing 5.Measurement of conductivity:400ESCan accurately measure the original conductivity of the sample water, and useUSPCalibrate the temperature compensation table. 6.Excellent calibration stability: The calibrated instrument can be used stably6A month. 7.Comprehensive verification: simple and easy-to-useIQ/OQThe instruction manual provides validation of the instrument. The complete verification package includesPQAnd the complete set of software.SieversWe also provide on-site verification services. 8.Low maintenance: only requires a maximum of one per year15The maintenance procedure can be completed in minutes without the need for reagents or gas sources. 9.Complete standard products provided:SieversThere is a complete series of standard products available for users to perform system stability and calibration procedures. be-allTOCBoth conductivity standards can be traced back toUSPperhapsNIST. Technical Parameter Operating instructions TOCRange:1.0ppb-2,500ppbasC TOCOnline accuracy:±0.5ppbOr measured values±1%Take the bigger one TOCOnline accuracy:±2ppbOr measured values±5%Take the bigger one Conductivity range:0.05-45μS/cm Conductivity accuracy: ±1% Conductivity accuracy: ±2% Interference: Slow response to interference from organic substances other than carbon and ozone water Display output:3position correcting:6Monthly stability Analysis time:1,6,30,60Minutes (user selectable) Sample temperature:0 Sample pressure: maximum100psi Injection flow rate: at least15milliliter/minute Ozone limit: The amount of ozone that appears continuously can be400ppbThe periodic occurrence is1.5ppm Instrument Description Input:2An independent binary input port Output:2individual4-20mAThe port,1individualRS-232,1A printing port, dual automatic alarm,2An independent binary input port Display: With background light display Power Supply:100-120Vor230V-50/60Hz,35Watts Weight: Volume:38.6W×39.6H×20Dcm(15.2×15.6×7.9inches) Protection level: Waterproof Security guarantee:CEsupport 21CFRPart11:DataguardTMThe option meets the electronic signature requirements Standard products: used for calibration, linearity, system stability, and multiple standard products are available |