The oil fume is sucked into the electrostatic oil fume purifier by the fan, and some of the larger oil droplets and oil particles are trapped on the flow plate due to mechanical collision and obstruction. When the airflow enters the high-voltage electrostatic field, under the effect of the high-voltage electric field, the oil fume gas is ionized, the oil mist is charged, and most of it is degraded and carbonized; A small portion of fine oil particles move towards the positive and negative plates of the electric field under the electric field force and airflow effect of the adsorption electric field, and are collected on the plates and flow to the oil collection tray under the effect of their own gravity. They are discharged through the oil discharge channel, and the remaining micrometer sized oil mist is degraded into carbon dioxide and water by the electric field and ultimately discharged into clean air; Under the effect of the high-voltage generator, ozone is generated in the air inside the electric field, removing most of the odors in the flue gas.
Precautions for using oil fume purifier
1. Anti leakage measures should be taken at the connection points of each air duct. To ensure the infection efficiency of the equipment.
2. The variable diameter air duct adjacent to the inlet and outlet of the equipment should be as smooth as possible to ensure the infection efficiency of the equipment. It is necessary to install straight pipes that are more than 4 times longer than the pipe diameter and use smooth pipes to connect them.
3. To ensure infection results, some fans are assumed to have a higher air volume than the planned air volume of the equipment. The equipment must operate at the planned air volume, and users can use a frequency converter to control the fan or install a regulating valve device at the fan outlet to complete the operation.
4. Therefore, it is necessary to use soft connections when connecting the air ducts of the equipment's light fan. The device will not function properly if it is subjected to vibration during operation.
5. To reduce the additional resistance of the fan. It is best to keep a straight pipe section of 1-2 meters at the inlet of the fan.
6. When a unified exhaust fan is used for ventilation, multiple devices are used in parallel. It is also necessary to ensure that the share of air volume allocated to each device is close to its planned share of air volume.
7. The equipment should operate under negative wind pressure conditions to ensure its infection efficiency. It is necessary to place the fan in front of the equipment.