OIL 820 UV spectrophotometer oil analyzer

NegotiableUpdate on 02/05
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
OIL 820 UV spectrophotometer oil analyzer
Product Details

1. Compliant with national standards

National Environmental Protection Standards of the People's Republic of China“HJ970-2018”Water quality Determination of petroleum products UV spectrophotometry (trial)

2. Using reagents:

hexane

3. Technical principles

existpH2Under certain conditions, the oil substances in the sample were extracted with n-hexane. The extract was dehydrated with anhydrous sodium sulfate and then adsorbed with magnesium silicate to remove polar substances such as animal and plant oils225nmMeasure absorbance at wavelength, petroleum content and absorbanceThe value conforms to Lambert Beer's law.

4. application area

Used for the determination of petroleum in surface water, groundwater, and seawater

5. Technical indicators and related parameters

Test wavelength:225nm

Wavelength accuracy: ±0.5nm

resolving power:0.001 mg/L

Measurement range:0-50mg/L

Method detection limit: When the sample volume is500mL,The volume of the extraction solution is25mL, using2cmWhen using a quartz colorimetric dish, the detection limit is0.01mg/L.

Instrument detection limit:DL<0.04mg/L(Determination of n-hexane blank solution)11Secondary3timesSD

Minimum detectable concentration:0.002 mg/L(Concentration in water sample)

Accuracy error: ≤±2%

Repeatability:RSD2%

Linear correlation coefficient:r> 0.999

● Baseline stability:Real time automatic adjustment of zero point (eliminating the impact of baseline drift);

● Light source system:The light source uses deuterium lamps with high wavelength accuracy, and the lifespan can reach5000More than hours

Calibration method: Standard curve calibration

● Temperature Degree:-5-45

● Relative humidity:5%-95%

● Host power supply power:(220±22)V(50±1)Hz50VA

● Shell material: Overall engineering plastic structure(PC+ABS)Anti electromagnetic radiation treatment, impact resistance, anti-corrosion

● Weight:3kg

● Dimensions:320mm(long)×300mm(wide)×170mm(tall)

Concentration limits for petroleum in some environmental quality standards and emission standards in China

Standard Name

Standard number

Concentration limit (unit:mg/L

environmental quality standards for surface water

GB3838-2002

class i

class ii

class iii

Class IV

Class V

0.05

0.5

1.0

Sea water quality standard

GB3097-1997

class i

class ii

class iii

Class IV

0.05

0.30

0.50

Standards for drinking water quality

GB5749-2006

0.3

Water quality standard for fisheries

GB11607-89

0.05

Standards for irrigation water quality

GB5084-52

paddy

dry farming

vegetable

0.50

10.0

1.0

Environmental Quality Assessment Standards for Edible Agricultural Products Production Areas

HJ332-2006

paddy

dry farming

vegetable

0.50

10.0

1.0

Environmental Quality Evaluation Standards for Greenhouse Vegetable Production Areas

HJ333-2006

1.0