Nitto Precision Original Mitsubishi Chemical Coulombic Method Bromine Value/Bromine Index Tester CA-310CB

1. Overview
This device is mainly used for: determining the content in samplesunsaturated hydrocarbonThe content.
Unit name: Bromine index mgBr/100g, Bromine valence gBr/100g
2. Technical performance
2.1 Compliance with standards
GB/T 1815-2019 Determination of Bromine Value and Bromine Index of Benzene Products
SH/T 1551-2018 Determination of Bromine Index of Industrial Aromatic Hydrocarbons Coulombic Titration Method
SH/T 0630-1996 Determination of Bromine Value and Bromine Index of Petroleum Products (Electricity Method)
ASTM D1492-13 Determination of Bromine Index for Industrial Aromatic Hydrocarbons Coulombic Titration Method
2.2 Technical Principles
Equipped with dual platinum needle indicator electrodes, electrodes with or without membranes, sealed titration cells, and magnetic stirring devices, it has a constant current measurement mode with adjustable electrolytic current and a dual volt ampere potentiometric endpoint indicator mode, which can automatically display time and electrolytic oxidation of Br-Generate Br2Power consumption.
3. Instrument features
★ (1) It is possible to schedule a time for automatic startup and instrument stabilization, reducing the long waiting time before testing.
★ (2) High speed electrolysis mode: The stable speed and detection speed of the instrument are faster, which improves detection efficiency and indirectly reduces the loss of reagents and other consumables.
★ (3) Standard Operating Procedure Record (S.O.P): A standard operating procedure for testing a certain sample can be entered into the instrument, and the instrument will automatically prompt the experimenter to perform sample testing according to the standard operating method.
(4) 8.4-inch color touch screen display with intuitive and clear operation interface, optional Chinese operation interface.
(5) Equipped with LIMS data transmission function.
★ (6) The main console can connect up to 4 detection channels, which can provide better reference for experimental results and improve detection efficiency.
(7) The main control panel can wirelessly control the detection channel (optional) for remote control of the testing module, in order to reduce the time required to release hazardous samples.
(8) You can choose electrodes with or without a diaphragm for clicking.
(9) Optional automatic liquid supply/discharge device for easy replacement of reagents.