Nitrogen blower for fermentation research1、 Technical parameters and characteristics:
1Sample quantity: not less than24Position, suitable for chromatographic bottles(2ml)TheCentrifugal tubeTest tube (beaker), and suitable for no less than12Position:30-56mmTest tube (beaker);
2Applicable centrifuge tubes, chromatography bottles, test tubes (beakers) size:8- 30 mmF30-56mm;
3Heating method; Constant temperature water bath;
4Gas flow meter:0-15L/min;
5Nitrogen consumption:330ml/min/Sample;
6Temperature control accuracy: ±1℃;
7Display mode: digital display;
8Temperature control range: room temperature-100℃,And it can be achievedSetting the temperatureOver-temperature alarmprompt;
9Disposable blowing needles and blowing steel needles can be used simultaneously or replaced at any time, effectively preventing cross contamination;
10The instrument has a drainage valve, which makes drainage more convenient and convenient;
11Suitable for beakers, test tubes, and chromatography bottles、Various sample instruments such as conical flasks and centrifuge tubes;
12The height and gas flow rate of each blowing needle tube are independently adjusted and controlled;
13Rotating sample holder, infinite rotation (front contact with sample, easy to operate);
14A gas flow meter with a needle valve controls and displays the total gas consumption, reducing costs.
15Heating method: Use constant temperature waterbathHeating method;
16Each sample grade has a numerical code;
17The body is designed as an integrated unit, and the material used isstainless steelcanAcid and alkali resistance, corrosion resistance, and high temperature resistance;
18Nitrogen blower for fermentation researchthermostathavetimingfunction;
Temperature control range: room temperature-100℃,And it can be achievedSetting the temperatureOver-temperature alarmprompt;
9Disposable blowing needles and blowing steel needles can be used simultaneously or replaced at any time, effectively preventing cross contamination;
10The instrument has a drainage valve, which makes drainage more convenient and convenient;
11Suitable for beakers, test tubes, and chromatography bottles、Various sample instruments such as conical flasks and centrifuge tubes;
12The height and gas flow rate of each blowing needle tube are independently adjusted and controlled;
13Rotating sample holder, infinite rotation (front contact with sample, easy to operate);
14A gas flow meter with a needle valve controls and displays the total gas consumption, reducing costs.
15Heating method: Use constant temperature waterbathHeating method;
16Each sample grade has a numerical code;
17The body is designed as an integrated unit with a PTFE layer