New and NEWALL Ball Grid Gauge E700-M Digital Display from the UKIntroduction:
NEWALL ball grid ruler has strong adaptability to the environment, effectively ensuring the accuracy of machining dimensions. Easy to install, no processing requirements for the installation surface, and no need for daily maintenance. Both analog and digital outputs, as well as CNC digital displays, can be used. Since the introduction of NEWALL ball grid ruler digital display in China, this product has become increasingly recognized by a large number of machine tool customers. Many domestic machine tool manufacturers choose to use it as a supporting product, and at the same time, some ball grid digital displays are used for the digital transformation of old machine tools. The measurement stroke of a single ball grid ruler is from50Millimeters to11.7The meter can be infinitely extended when connected, and the high-precision ball grid ruler has the characteristics of high reliability and maintenance free, ensuring reliable use.
Features:
The ball grid ruler is highly reliable, waterproof, oil resistant, dustproof, iron chip resistant, vibration resistant, and anti-interference.
Protection level IP67;
Dustproof, oil proof, and iron chip proof, capable of working in harsh environments;
No mechanical wear and tear;
No need for daily cleaning and maintenance;
Resistance to impact and vibration;
High reliability;
parameter
Technical specifications |
Ball grid ruler |
Micro grid ruler |
Measurement resolution |
0.005mm/0.001mm |
0.001mm/0.0005mm |
measurement accuracy |
±(0.01+0.005/m)mm |
±0.005mm |
running speed |
2m/sec |
0.75m/sec |
valid itinerary |
50-11684mm(>30m) |
50-1050mm |
signal output |
Sin/CosorRS422-TTL |
Sin/CosorRS422-TTL |
Reading head size |
54mm*131mm*28mm |
35mm*75mm*25mm |
Protection level |
IP67(iec529) |
IP67(iec529) |
impact-resistant |
100g(IEC69-2-6) |
100g(IEC69-2-6) |
Vibration resistant |
30g(IEC-2-27) |
30g(IEC-2-27) |
coefficient of thermal expansion |
12*10-6/°K |
12*10-6/°K |
Newall Ball Grid Gauge Reading Head Technical Specifications: Technical Parameters Ball Grid Gauge SPHEROSYN Micro Grid Gauge MICROSYN
Newall ball grid ruler reading head measurement resolution 0.005mm/0.001mm
Newall ball grid ruler reading head measurement accuracy ± (0.01+0.005/m) mm ± 0.005mm
Newall ball grid ruler reading head with high running speed of 2m/sec 0.75m/sec
Effective travel: 50-11684mm (>30m) 50-1050mm
Newall ball grid ruler reading head signal output Sin/Cos or RS422-TTL Sin/Cos or RS422-TTL
New and NEWALL Ball Grid Gauge E700-M Digital Display from the UKCommon faults and troubleshooting methods:
1. Digital display meter black screen
Solution: The digital display may be in sleep mode. Pull any key to return the digital display to its normal working state;
Check if the power cord plug of the digital display is properly plugged in;
Check if the power cord is damaged:
Check if the voltage of the switch power supply is within the range of 15-24VDC ± 10%;
Check if the power indicator light on the front of the digital display has been fully lit.
2. The digital display meter often restarts itself during operation
Check if the power supply voltage is too low or when the voltage is unstable,
Check if the output voltage of the switch power supply is within the range of 15-24VDC ± 10%;
Check if the wiring of each power plug is good.
3. The digital display meter jumps large or the last few digits shake
Check if the digital display is grounded and if the grounding is good;
Check all cable connections for looseness or poor contact;
Check if there is a malfunction in the ball grid sensor and signal extension cable.
4When pressing the button, the digital display shows no response
Panel malfunction;
Unplug the power plug and power it back on after 15 seconds.
Check if the digital display is connected to a sensing circuit;
Check for any damage to sensors, cables, and connections;
Power off the enemy display and restart:
Unplug the sensor connector of the shaft and replace it with another shaft to determine whether it is a fault with the digital display or the sensor.
Check if the sensor type settings are correct:
Check the diameter/radius reading setting of the axis. When set to diameter, the digital display reading is twice the actual value of the monk;
Check if the number of error compensation coefficients is too large;
If segmented error compensation is used, please verify and determine the compensation data
Unplug the sensor connector of the shaft and switch to another shaft to determine if it is a sensor circuit fault:
Check for damage to sensors or cables
Check if the installation of the ball grid ruler or reading head is in accordance with the installation instructions;
Loosen the central screws of the two end ruler brackets, gently move the ball ruler left and right, and judge whether there are foreign objects on the ball grid ruler or reading head based on the resistance of the movement:
Take out the ball ruler and place it on the machine guide rail or other platform. Gently roll the ruler body to check if there is any bending phenomenon on the ball ruler.