parameter |
Indicator |
Particle size range |
0.1-3500 microns (different ranges can be selected to achieve the highest testing accuracy) |
measurement accuracy |
σ<0.04% (error in repeated testing results of a single sample of the same product) σ<0.3% (error in test results of repeated sampling of the same product) |
light source |
5mw helium neon laser, wavelength 632.8nm |
detector |
Fully automatic quasi linear focusing system, multiple detectors, scanning rate: 2000 times/second |
Testing time |
Within 10 seconds (from sample injection to test report output) |
data transmission |
High speed TCP/IP transmission |
obscuration |
Up to 50%* |
Sample size |
Milligram kilogram |
Automatic sampling method |
Vibration groove funnel feeding (conventional material) Rotary brush wheel feeding (for sticky materials) Gas suction feed (materials with low density and easy dispersion) |
Dispersing medium |
Compressed gas (air or inert gas) |
Disperse pressure |
0.1-6Bar (adjusted according to the characteristics of the material) |
Dispersion tube lifespan |
Disperse 2.5 grams of Potland cement each time, at least 100000 times |
data processing |
Fraunhofer or Mie theory |
Result output format |
Standard granularity distribution curve, customer customized format result output, etc |
Supporting documents |
Complete set of instrument operation and maintenance manual, software operation manual in both Chinese and English, original CD of instrument software, system recovery CD, and CD of instrument configuration list |
Operation method |
Software Control Standard Operating Procedure (SOP) |
Power Supply |
AC65-260V, 50/60Hz |
Environmental requirements |
Temperature: 0-40 ℃, humidity ≤ 80%, no condensation |
For large particles, they can be dispersed by the gravity of the particles themselves. New Patek Company can provide a dry gravity dispersion laser particle size analyzer (model: HELOS/GRADIS, Test range: 0.5-8750 micrometers).
Example:
Comparison of dispersion test results of HELOS&RODOS: NdFeB dry wet method using dry laser particle size analyzer:

1. Dry sample testing does not require any dispersants or solvents;
2. Instantaneous dispersion and measurement, fast testing accuracy, high analysis efficiency, and only a few seconds from sample injection to result output;