Welcome Customer !

Membership

Help

Beijing Duktech Technology Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Beijing Duktech Technology Co., Ltd

  • E-mail

    41711365@qq.com

  • Phone

    18518707030

  • Address

    813, 8th Floor, No. 15 Information Road, Haidian District, Beijing

Contact Now

NOVEC photoacoustic spectroscopy gas analyzer

NegotiableUpdate on 01/04
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The DKG ONE-NOVEC analyzer is based on ultra sensitive cantilever beam enhanced photoacoustic spectroscopy detection technology, combined with quantum cascade laser (QCL) light source, and operates on the mid infrared basic spectral absorption peak of NOVEC. The combination of these two provides an ultra-high level of stability, with recalibration cycles lasting several months or even years, greatly reducing overall holding costs.
Product Details

NOVEC photoacoustic spectroscopy gas analyzer

Testing requirements:

NOVEC is commonly used as a fire extinguishing agent. After extinguishing the fire, its concentration must be monitored in real time to ensure the safety of personnel entering the fire scene and the effectiveness of the fire extinguishing.

NOVEC 光声光谱气体分析仪

NOVEC photoacoustic spectroscopy gas analyzer

Technical application:

The DKG ONE-NOVEC analyzer is based on ultra sensitive cantilever beam enhanced photoacoustic spectroscopy detection technology, combined with quantum cascade laser (QCL) light source, and operates on the mid infrared basic spectral absorption peak of NOVEC. The combination of these two provides an ultra-high level of stability, with recalibration cycles lasting several months or even years, greatly reducing overall holding costs.

NOVEC 光声光谱气体分析仪NOVEC 光声光谱气体分析仪

Ultra sensitive optical cantilever microphone

NOVEC photoacoustic spectroscopy gas analyzer

Technical advantages:


Adopting photoacoustic spectroscopy technology, high sensitivity and rapid response;

Direct absorption measurement without drift;

Low sample size, no consumables required;

Wide dynamic range, sub ppb level detection lower limit;

Independent operating system with built-in gas exchange pump;

Stable operation, long recalibration interval (several months).


NOVEC 光声光谱气体分析仪

NOVEC photoacoustic spectroscopy gas analyzer

Technical Principle

Working principle: Infrared photoacoustic spectroscopy

Ultra sensitive optical microphone, based on micro motor cantilever sensor, combined with laser interferometer to measure the micro motion of cantilever beam

Light source: distributed feedback quantum cascade laser

The temperature of the sample pool remains stable at 50 ℃


NOVEC photoacoustic spectroscopy gas analyzer

detection parameters

Response time: Depending on the channel integration time (C.I.T.) and gas replacement cycle, typically ranging from 3 seconds to 3 minutes

Detection limit: 0.1ppb

Dynamic Range: Typical Level 5 (100000 times detection limit)

Repeatability: Measurement values less than 1% at standard concentrations under working conditions

Accuracy: depends on the accuracy of the calibration concentration standard gas, typically 2-5%

Temperature stability: No impact within the working temperature range

Pressure stability: No impact within the pressure working range


NOVEC photoacoustic spectroscopy gas analyzer

General

19 "3 U industrial chassis, suitable for all desktop or rack mounted fixed installations

尺寸: 48.4cm W x 13.9cm H x 44cm D(19.1 In W x 5.5 in H x 17.3 in D)

Weight: Approximately 13kg

Embedded computer with built-in 7 "front display

The data storage capacity is sufficient for continuous monitoring for at least one year

Total gas production: 10-30ml

The rear panel has four gas interfaces, two of which are sampling interfaces, equipped with dust particle filters

Power supply:

Input voltage: 100-240VAC, 50-60 Hz

Input power: 100-200 W (depending on specific requirements)

Communication interfaces: Ethernet, USB


DKG ONE-NOVEC can be remotely controlled through a smartphone, tablet, computer, or another DKG ONE (upcoming)


NOVEC photoacoustic spectroscopy gas analyzer

environment

Operating conditions

Temperature range: 0 ℃ to+49 ℃

Humidity: No condensation

Pressure: 750mbar~1050 mbar

Dust/water rating: IP20 (IEC 529)

Storage conditions

Temperature range: -20 ℃ to+60 ℃

Sample gas conditions

Temperature range: 0 ℃ to+49 ℃

Humidity: No condensation, maximum relative humidity of 80% at a temperature of 35 ° C,

Linear decrease to 35% when the temperature reaches 49 ° C

Pressure: 750 mbar to 1050 mbar

Airflow: approximately 1L/min

Particles<1 μ m


NOVEC photoacoustic spectroscopy gas analyzer

Standard:

Compliant with the Low Voltage Directive 2014/35/EU, EMC Directive 2004/108/EC, and ROHS 2 Directive 2011/65/EU

NOVEC 光声光谱气体分析仪